Your browser doesn't support javascript.
loading
Efficiency, Precision, Validity, and Reliability of GlauCAT-Asian Computerized Adaptive Tests in Measuring Glaucoma-Related Quality of Life.
Fenwick, Eva K; Man, Ryan E K; Lim, Belicia; Baskaran, Mani; Nongpiur, Monisha; Sng, Chelvin C A; Iyer, Jayant Venkatramani; Husain, Rahat; Perera, Shamira; Wong, Tina; Low, Jin Rong; Huang, Olivia Shimin; Lun, Katherine; Loe, Bao Sheng; Aung, Tin; Lamoureux, Ecosse L.
Afiliación
  • Fenwick EK; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Man REK; Duke-NUS Medical School, National University of Singapore, Singapore, Singapore.
  • Lim B; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Baskaran M; Duke-NUS Medical School, National University of Singapore, Singapore, Singapore.
  • Nongpiur M; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Sng CCA; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Iyer JV; Medical and Vision Research Foundation, Sankara Nethralaya, Chennai, India.
  • Husain R; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Perera S; Duke-NUS Medical School, National University of Singapore, Singapore, Singapore.
  • Wong T; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Low JR; Department of Ophthalmology, National University of Singapore, Singapore, Singapore.
  • Huang OS; National University Health System, Singapore, Singapore.
  • Lun K; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Loe BS; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Aung T; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
  • Lamoureux EL; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore, Singapore.
Transl Vis Sci Technol ; 13(2): 6, 2024 02 01.
Article en En | MEDLINE | ID: mdl-38329749
ABSTRACT

Purpose:

To determine the efficiency, precision, and agreement of GlauCAT-Asian and its corresponding validity and reliability.

Methods:

In this cross-sectional study, 219 participants (mean ± standard deviation age, 66.59 ± 8.61 years; 34% female) across the spectrum of glaucoma severity and 50 glaucoma suspects were recruited from glaucoma clinics in Singapore. Participants answered seven computerized adaptive testing (CAT) evaluations (Ocular Comfort, Activity Limitation, Lighting, Mobility, Concerns, Psychosocial, Glaucoma Management) and underwent eye examinations. Efficiency (mean number of items required for each CAT and time taken for CAT versus full item banks [IBs]), agreement (concordance between CATs and full IB person measures, henceforth referred to as scores), and precision (standard error of measurement [SE]) were evaluated. Other validity and reliability metrics were also assessed.

Results:

The mean number of items administered ranged from 9 (Mobility/Glaucoma Management) to 12 (Ocular Comfort). Compared to answering the full IBs, CATs provided an average time saving of 38.3% (range, 10% to 70.6% for Lighting and Activity Limitation, respectively). Agreement between scores obtained by CAT versus full IB was high (intracorrelation coefficient ≥0.75), as was precision of score estimates (mean SE range 0.35 for Psychosocial to 0.29 for Mobility). Scores from Activity Limitation, Mobility, Lighting, and Concerns decreased significantly as glaucoma severity increased (criterion validity; P-trend <0.05). All tests displayed good convergent/divergent validity and test-retest reliability.

Conclusions:

GlauCAT-Asian provides efficient, precise, accurate, valid, and reliable measurement of the patient-centered impact of glaucoma. Translational Relevance GlauCAT-Asian may provide a valuable clinical tool for ophthalmologists to monitor impact of disease progression and the effectiveness of therapies.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Calidad de Vida / Glaucoma Tipo de estudio: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Aspecto: Patient_preference Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Transl Vis Sci Technol Año: 2024 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Calidad de Vida / Glaucoma Tipo de estudio: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Aspecto: Patient_preference Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Transl Vis Sci Technol Año: 2024 Tipo del documento: Article País de afiliación: Singapur Pais de publicación: Estados Unidos