Phase 3 Randomized Clinical Trial of the Safety and Efficacy of Travoprost Intraocular Implant in Patients with Open-Angle Glaucoma or Ocular Hypertension.
Ophthalmology
; 131(9): 1021-1032, 2024 Sep.
Article
en En
| MEDLINE
| ID: mdl-38423216
ABSTRACT
PURPOSE:
To evaluate the safety and intraocular pressure (IOP)-lowering efficacy of 2 models of the travoprost intraocular implant (fast-eluting [FE] and slow-eluting [SE] types) from 1 of 2 phase 3 trials (the GC-010 trial).DESIGN:
Multicenter, randomized, double-masked, sham-controlled, noninferiority trial.PARTICIPANTS:
Patients with open-angle glaucoma or ocular hypertension having an unmedicated baseline mean diurnal IOP (average of 8 am, 10 am, and 4 pm time points) of ≥ 21 mmHg, and IOP of ≤ 36 mmHg at each of the 8 am, 10 am, and 4 pm timepoints at baseline.METHODS:
Study eyes were randomized to the travoprost intraocular implant (FE implant [n = 200] or SE implant [n = 197] model) or to timolol ophthalmic solution 0.5% twice daily (n = 193). MAIN OUTCOMEMEASURES:
The primary outcome was mean change from baseline IOP in the study eye at 8 am and 10 am, at each of day 10, week 6, and month 3. Safety outcomes included adverse events (AEs) and ophthalmic assessments.RESULTS:
Mean IOP reduction from baseline over the 6 time points ranged from 6.6 to 8.4 mmHg for the FE implant group, from 6.6 to 8.5 mmHg for the SE implant group, and from 6.5 to 7.7 mmHg for the timolol group. The primary efficacy end point was met; the upper limit of the 95% confidence interval of the difference between the implant groups and the timolol group was < 1 mmHg at all 6 time points. Study eye AEs, most of mild or moderate severity, were reported in 21.5%, 27.2%, and 10.8% of patients in the FE implant, SE implant, and timolol groups, respectively. The most common AEs included iritis (FE implant, 0.5%; SE implant, 5.1%), ocular hyperemia (FE implant, 3.0%; SE implant, 2.6%), reduced visual acuity (FE implant, 1.0%; SE implant, 4.1%; timolol, 0.5%), and IOP increased (FE implant, 3.5%; SE implant, 2.6%; timolol, 2.1%). One serious study eye AE occurred (endophthalmitis).CONCLUSIONS:
The travoprost intraocular implant demonstrated robust IOP reduction over the 3-month primary efficacy evaluation period after a single administration. The IOP-lowering efficacy in both implant groups was statistically and clinically noninferior to that in the timolol group, with a favorable safety profile. FINANCIAL DISCLOSURE(S) Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.Palabras clave
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Tonometría Ocular
/
Glaucoma de Ángulo Abierto
/
Hipertensión Ocular
/
Implantes de Medicamentos
/
Travoprost
/
Presión Intraocular
/
Antihipertensivos
Límite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Ophthalmology
Año:
2024
Tipo del documento:
Article
Pais de publicación:
Estados Unidos