Your browser doesn't support javascript.
loading
An Autocollimator Axial Measurement Method Based on the Strapdown Inertial Navigation System.
Ma, Wenjia; Li, Jianrong; Liu, Shaojin; Han, Yan; Liu, Xu; Wang, Zhiqian; Jiang, Changhong.
Afiliación
  • Ma W; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Li J; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Liu S; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Han Y; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Liu X; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
  • Wang Z; University of Chinese Academy of Sciences, Beijing 100049, China.
  • Jiang C; Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China.
Sensors (Basel) ; 24(8)2024 Apr 18.
Article en En | MEDLINE | ID: mdl-38676206
ABSTRACT
Autocollimators are widely used optical axis-measuring tools, but their measurement errors increase significantly when measuring under non-leveled conditions and they have a limited measurement range due to the limitations of the measurement principle. To realize axis measurement under non-leveled conditions, this paper proposes an autocollimator axis measurement method based on the strapdown inertial navigation system (SINS). First, the measurement model of the system was established. This model applies the SINS to measure the change in attitude of the autocollimator. The autocollimator was then applied to measure the angular relationship between the measured axis and its own axis, based on which the angular relationship of the axis was measured via computation through signal processing and data fusion in a multi-sensor system. After analyzing the measurement errors of the system model, the Monte Carlo method was applied to carry out a simulation analysis. This showed that the majority of the measurement errors were within ±0.002° and the overall measurement accuracy was within ±0.006°. Tests using equipment with the same parameters as those used in the simulation analysis showed that the majority of the measurement errors were within ±0.004° and the overall error was within ±0.006°, which is consistent with the simulation results. This analysis proves that this method solves the problem of the autocollimator being unable to measure the axis under non-leveled conditions and meets the needs of axis measurement with the application of autocollimators under a moving base.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Sensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: China Pais de publicación: Suiza