Objective:
This study investigated the clinical effects and applicability of minimally invasive impacted teeth extraction using digital robots.Methods:
A marker was bonded to the non-surgical area before surgery. A Cone-Beam Computed Tomography (CBCT) scan was obtained and uploaded to the robot software to determine the drilling position of the ring drill. During the surgery, the robot arm automatically navigated to a predetermined position, and the ring drill removed part of the bone tissue and exposed and extracted the impacted teeth. Finally, the surgeon tightly sutured the wounds to the surgical area.Results:
Three minimally invasive extractions of impacted teeth with robotic assistance were performed without complications. The surgical area showed good healing during the one-month follow-up examination.Conclusions:
Digital robot-assisted minimally invasive extraction of impacted teeth is a highly feasible clinical procedure as it minimises trauma to the surgical area and protects the surrounding blood vessels and nerve bundles, making it a safe and valuable technique with significant potential for clinical application.