Your browser doesn't support javascript.
loading
Optimization of Non-Alloyed Backside Ohmic Contacts to N-Face GaN for Fully Vertical GaN-on-Silicon-Based Power Devices.
Hamdaoui, Youssef; Vandenbroucke, Sofie S T; Michler, Sondre; Ziouche, Katir; Minjauw, Matthias M; Detavernier, Christophe; Medjdoub, Farid.
Afiliación
  • Hamdaoui Y; Institute of Electronics, Microelectronics and Nanotechnology, CNRS-IEMN, 59650 Lille, France.
  • Vandenbroucke SST; Department of Solid State Sciences, CoCooN Group, Ghent University, Krijgslaan 281/S1, B-9000 Ghent, Belgium.
  • Michler S; Department of Solid State Sciences, CoCooN Group, Ghent University, Krijgslaan 281/S1, B-9000 Ghent, Belgium.
  • Ziouche K; Department Innovation Management Siltronic AG, Einsteinstraße 172, 81677 München, Germany.
  • Minjauw MM; Institute of Electronics, Microelectronics and Nanotechnology, CNRS-IEMN, 59650 Lille, France.
  • Detavernier C; Department of Solid State Sciences, CoCooN Group, Ghent University, Krijgslaan 281/S1, B-9000 Ghent, Belgium.
  • Medjdoub F; Department of Solid State Sciences, CoCooN Group, Ghent University, Krijgslaan 281/S1, B-9000 Ghent, Belgium.
Micromachines (Basel) ; 15(9)2024 Sep 15.
Article en En | MEDLINE | ID: mdl-39337817
ABSTRACT
In the framework of fully vertical GaN-on-Silicon device technology development, we report on the optimization of non-alloyed ohmic contacts on the N-polar n+-doped GaN face backside layer. This evaluation is made possible by using patterned TLMs (Transmission Line Model) through direct laser writing lithography after locally removing the substrate and buffer layers in order to access the n+-doped backside layer. As deposited non-alloyed metal stack on top of N-polar orientation GaN layer after buffer layers removal results in poor ohmic contact quality. To significantly reduce the related specific contact resistance, an HCl treatment is applied prior to metallization under various time and temperature conditions. A 3 min HCl treatment at 70 °C is found to be the optimum condition to achieve thermally stable high ohmic contact quality. To further understand the impact of the wet treatment, SEM (Scanning Electron Microscopy) and XPS (X-ray Photoelectron Spectroscopy) analyses were performed. XPS revealed a decrease in Ga-O concentration after applying the treatment, reflecting the higher oxidation susceptibility of the N-polar face compared to the Ga-polar face, which was used as a reference. SEM images of the treated samples show the formation of pyramids on the N-face after HCl treatment, suggesting specific wet etching planes of the GaN crystal from the N-face. The size of the pyramids is time-dependent; thus, increasing the treatment duration results in larger pyramids, which explains the degradation of ohmic contact quality after prolonged high-temperature HCl treatment.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Suiza

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Micromachines (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Francia Pais de publicación: Suiza