Quantitative GLC determination of oxycodone in human plasma.
J Pharm Sci
; 68(1): 43-5, 1979 Jan.
Article
en En
| MEDLINE
| ID: mdl-758463
A GLC assay was developed for the determination of oxycodone levels in human plasma using a nitrogen-specific detector. The assay was developed for use in bioavailability studies of therapeutic doses of oxycodone. After ingestion of a commerical tablet containing 4.5 mg of oxycodone hydrochloride and 0.38 mg of oxycodone terephthalate by six volunteers, the mean peak oxycodone concentration in plasma was 18.4 ng/ml at 1 hr.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Oxicodona
/
Codeína
Límite:
Adult
/
Humans
/
Male
Idioma:
En
Revista:
J Pharm Sci
Año:
1979
Tipo del documento:
Article
Pais de publicación:
Estados Unidos