Quantitative GLC determination of oxycodone in human plasma.
J Pharm Sci ; 68(1): 43-5, 1979 Jan.
Article en En | MEDLINE | ID: mdl-758463
A GLC assay was developed for the determination of oxycodone levels in human plasma using a nitrogen-specific detector. The assay was developed for use in bioavailability studies of therapeutic doses of oxycodone. After ingestion of a commerical tablet containing 4.5 mg of oxycodone hydrochloride and 0.38 mg of oxycodone terephthalate by six volunteers, the mean peak oxycodone concentration in plasma was 18.4 ng/ml at 1 hr.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Oxicodona / Codeína Límite: Adult / Humans / Male Idioma: En Revista: J Pharm Sci Año: 1979 Tipo del documento: Article Pais de publicación: Estados Unidos