Your browser doesn't support javascript.
loading
The clinical application value of different localization methods in thoracoscopic resection of pulmonary nodules / 介入放射学杂志
Article en Zh | WPRIM | ID: wpr-1018826
Biblioteca responsable: WPRO
ABSTRACT
Objective To compare the clinical application value of medical glue and a new-type medical anchor positioning needle in thoracoscopic resection of pulmonary nodules.Methods A total of 182 patients with pulmonary nodules,who received video-assisted thoracic surgery(VATS)at the Department of Thoracic Surgery of Affiliated Hospital of Shaoxing University of China between January 2020 and December 2022,were enrolled in this study.Preoperative CT-guided localization of the pulmonary nodule was performed in all patients,including medical glue positioning in 89 patients(medical glue group)and anchor needle positioning in 93 patients(anchor needle group).The incidences of pneumothorax and bleeding,the time spent for positioning,the interval between localization and operation,the time spent for operation,and the radiation dose during localization process were recorded and the data were statistically analyzed.Results The success rate of positioning was 100%(93/93)in the anchor needle group and 96.7%(86/89)in the medical glue group.There was no statistically significant difference between the two groups(P>0.05).The incidence of bleeding was 31.2%(29/93)in the anchor needle group and 15.7%(14/89)in the medical glue group,and the difference between the two groups was statistically significant(P<0.05).The incidence of pneumothorax was 30.1%(28/93)in the anchor needle group and 20.2%(18/89)in the medical glue group,and there was no significant difference between the two groups(P>0.05).No statistically significant difference in the time spent for operation existed between the two groups(P>0.05).The time spent for positioning and the interval between localization and operation in the medical glue group were longer than those in the anchor needle group,and the radiation dose in the medical glue group was higher than that in the anchor needle group,and the differences between the two groups were statistically significant(P<0.05).Conclusion For the preoperative localization of ground glass opacity(GGO)or solitary pulmonary nodule(SPN),both medical glue positioning method and anchor needle positioning method have high clinical application value.The clinical and interventional physicians should adopt appropriate positioning method according to the patient's condition.
Palabras clave
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Journal of Interventional Radiology Año: 2024 Tipo del documento: Article
Texto completo: 1 Base de datos: WPRIM Idioma: Zh Revista: Journal of Interventional Radiology Año: 2024 Tipo del documento: Article