BACKGROUND:

The Spectra Optia (SPO) is a novel continuous-flow centrifugal apheresis system based on the COBE Spectra (CSP) platform. There have been few attempts to validate the advantages of the SPO. We performed a retrospective study comparing the two cell separators for therapeutic plasma exchange (TPE) procedures in kidney transplant (KT) patients and seeing efficacy and safety.

METHODS:

We analyzed 720 TPE procedures performed between August 2012 and July 2014. Procedures included desensitization TPE before KT and TPE for the management of acute and chronic antibody-mediated graft rejection. Demographic characteristics, operational TPE variables, and laboratory data were analyzed.

RESULTS:

Demographic characteristics for the SPO (n=389) and CSP (n=331) groups did not differ significantly. The procedure time to exchange one plasma volume was 94.2+/-10.3 min in the SPO group and 100.4+/-11.2 min in the CSP group (P<0.001). The plasma removal efficiency (PRE) was 92.5+/-4.9% in the SPO group and 83.2+/-3.7% in the CSP group (P<0.001). There were no significant differences across the two apheresis systems for changes in hematologic parameters.

CONCLUSIONS:

Compared with the CSP, the SPO was associated with an improved PRE and a shorter procedure time to exchange one plasma volume. Our results in KT patients show that the SPO is superior to the CSP in TPE procedures.
Asunto(s)

Texto completo: Disponible Base de datos: WPRIM (Pacífico Occidental) Asunto principal: Plasma / Intercambio Plasmático / Volumen Plasmático / Eliminación de Componentes Sanguíneos / Estudios Retrospectivos / Trasplante de Riñón / Rechazo de Injerto / Riñón Tipo de estudio: Estudio observacional / Factores de riesgo Límite: Humanos Idioma: Inglés Revista: Annals of Laboratory Medicine Año: 2015 Tipo del documento: Artículo
Texto completo: Disponible Base de datos: WPRIM (Pacífico Occidental) Asunto principal: Plasma / Intercambio Plasmático / Volumen Plasmático / Eliminación de Componentes Sanguíneos / Estudios Retrospectivos / Trasplante de Riñón / Rechazo de Injerto / Riñón Tipo de estudio: Estudio observacional / Factores de riesgo Límite: Humanos Idioma: Inglés Revista: Annals of Laboratory Medicine Año: 2015 Tipo del documento: Artículo
...