Simultaneous determination of tectorigenin-7-O-xylosylglucosid, tectoridin and tectorigenin in flowers of Pueraria lobata by HPLC / 中国中药杂志
China Journal of Chinese Materia Medica
; (24): 2308-2311, 2010.
Artículo
en Chino
| WPRIM (Pacífico Occidental)
| ID: wpr-262170
Biblioteca responsable:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To develop a HPLC method for the simultaneous determination of tectorigenin-7-O-xylosylglucosid, tectoridin and tectorigenin in flowers of Pueraria lobata.</p><p><b>METHOD</b>The separation was performed on a Kromasil C18 column (4.6 mm x 250 mm, 5 microm), using a gradient elution with acetonitrile-water containing 0.2% phosphoric acid as the mobile phase. The flow rate was 1.0 mL x min(-1), the detection wavelength was 265 nm and the temperature of column was 35 degrees C.</p><p><b>RESULT</b>The linear ranges of tectorigenin-7-O-xylosylglucosid, tectoridin and tectorigenin were 0.14-1.40 (r = 0.9994), 0.20-2.02 (r = 0.9993), and 0. 10-1.04 (r = 0.9991) , respectively. The average recoveries (n=6) of the three constituents were 99.5% (RSD 1.8%), 99.6% (RSD 1.7%), and 99.8% (RSD 1.9%), respectively.</p><p><b>CONCLUSION</b>The method is simple and accurate with a good eata and can be used as a quality control method for flowers of P. lobata of different sources.</p>
Texto completo:
Disponible
Base de datos:
WPRIM (Pacífico Occidental)
Asunto principal:
Medicamentos Herbarios Chinos
/
Química
/
Cromatografía Líquida de Alta Presión
/
Pueraria
/
Flores
/
Glucósidos
/
Isoflavonas
/
Métodos
Idioma:
Chino
Revista:
China Journal of Chinese Materia Medica
Año:
2010
Tipo del documento:
Artículo