Evaluación del desempeño de dos pruebas para la detección de antígeno de Helicobacter pylori en heces / Evaluation of the accuracy of two stool antigen tests for Helicobacter pylori infection
Rev. cuba. med. trop
; 69(1): 1-7, ene.-abr. 2017.
Artigo
em Espanhol
| LILACS, CUMED
| ID: biblio-1042914
Biblioteca responsável:
CU1.1
RESUMEN
Introducción:
la detección de antígeno en heces se ha considerado una prueba prometedora para el diagnóstico de la infección por Helicobacter pylori. Para su introducción en la práctica médica, es un requisito indispensable demostrar el desempeño adecuado del método en la población de estudio.Objetivo:
evaluar la capacidad diagnóstica de los sistemas comerciales ELISA SD y SD BIOLINE, del fabricante Standard Diagnostics, Corea, en pacientes cubanos con síntomas gastroduodenales.Métodos:
se evaluaron 101 muestras de heces de pacientes previamente clasificados como H. pylori positivos y negativos por las pruebas de referencia de histología y prueba rápida de la ureasa. Se calcularon los parámetros de desempeño de ambos sistemas diagnósticos por el programa EPIDAT 3.1.Resultados:
la sensibilidad para los sistemas ELISA SD y SD BIOLINE fue de 85,25 por ciento y 75,41 por ciento, respectivamente. La especificidad para ambos fue de 92,50 por ciento. Los valores predictivos positivos y negativos, los índices de validez y de Youden y la confiabilidad diagnóstica de ambas pruebas fueron satisfactorios.Conclusiones:
Los sistemas evaluados exhibieron un desempeño comparable con la histología y la prueba rápida de ureasa para la detección activa de la infección por H. pylori, lo que demuestra su utilidad para el diagnóstico y el manejo oportuno del paciente, sin la necesidad de emplear pruebas invasivas(AU)ABSTRACT
Introduction:
stool antigen tests have been considered to be promising for the diagnosis of Helicobacter pylori infection. For their incorporation into medical practice, it is indispensable to demonstrate their accuracy in a study population.Objective:
evaluate the diagnostic capacity of the commercial systems ELISA SD and SD BIOLINE, Standards Diagnostics, Korea, in Cuban patients with gastroduodenal symptoms.Methods:
an evaluation was conducted of 101 stool samples from patients previously classified as H. pylori positive and negative by reference histological tests and the rapid urease test. Estimation was made of performance parameters for both diagnostic systems using the software EPIDAT 3.1.Results:
Sensitivity for the systems ELISA SD and SD BIOLINE was 85.25 percent and 75.41 percent, respectively. Specificity for both was 92.50 percent. Positive and negative predictive values, validity and Youden's indices, and diagnostic reliability were satisfactory for both tests.Conclusions:
the systems evaluated were found to have a performance level comparable with histological tests and the rapid urease test for active detection of H. pylori infection. This confirms their usefulness for the diagnosis and timely management of patients without having to use invasive tests(AU)
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Contexto em Saúde:
Doenças Negligenciadas
Problema de saúde:
Zoonoses
Base de dados:
CUMED
/
LILACS
Assunto principal:
Ensaio de Imunoadsorção Enzimática
/
Fezes
/
Antígenos
Tipo de estudo:
Estudo diagnóstico
/
Guia de prática clínica
/
Estudo observacional
/
Estudo prognóstico
/
Fatores de risco
Limite:
Humanos
Idioma:
Espanhol
Revista:
Rev. cuba. med. trop
Assunto da revista:
Medicina Tropical
Ano de publicação:
2017
Tipo de documento:
Artigo
País de afiliação:
Cuba
Instituição/País de afiliação:
Instituto de Medicina Tropical Pedro Kourí/CU
/
Policlínico Eduardo Díaz/CU
/
Policlínico Pedro Borrás/CU