Your browser doesn't support javascript.
loading
Development and validation of a UHPLC-ESI-MS/MS method for the quantification of artepillin C in Brazilian green propolis
Riani, Lorena Rodrigues; Silva, Lívia Mara; Silva, Ohana Oliveira Zuza da; Junqueira, Lauriene Ricardo; Nascimento, Jorge Willian Leandro; Silva Filho, Ademar Alves da.
Afiliação
  • Riani, Lorena Rodrigues; Departamento de Ciências Farmacêuticas. Faculdade de Farmácia. Universidade Federal de Juiz de Fora (UFJF). Juiz de Fora. BR
  • Silva, Lívia Mara; Departamento de Ciências Farmacêuticas. Faculdade de Farmácia. Universidade Federal de Juiz de Fora (UFJF). Juiz de Fora. BR
  • Silva, Ohana Oliveira Zuza da; Departamento de Ciências Farmacêuticas. Faculdade de Farmácia. Universidade Federal de Juiz de Fora (UFJF). Juiz de Fora. BR
  • Junqueira, Lauriene Ricardo; Departamento de Ciências Farmacêuticas. Faculdade de Farmácia. Universidade Federal de Juiz de Fora (UFJF). Juiz de Fora. BR
  • Nascimento, Jorge Willian Leandro; Departamento de Ciências Farmacêuticas. Faculdade de Farmácia. Universidade Federal de Juiz de Fora (UFJF). Juiz de Fora. BR
  • Silva Filho, Ademar Alves da; Departamento de Ciências Farmacêuticas. Faculdade de Farmácia. Universidade Federal de Juiz de Fora (UFJF). Juiz de Fora. BR
Rev. ciênc. farm. básica apl ; Rev. ciênc. farm. básica apl;42: 1-13, 20210101.
Article em En | LILACS-Express | LILACS | ID: biblio-1224639
Biblioteca responsável: BR1851.9
ABSTRACT

Objectives:

The aim of this study was the development and validation of a fast method to quantify artepillin C in green propolis using ultra high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS).

Methods:

High purity (97.8%) artepillin C was isolated from green propolis using chromatography techniques. Quantification was performed using a C18 (2.1 x 100 mm; 1.7 µm) column, gradient of water and methanol (with 0.01% formic acid) as mobile phase, at a flow rate of 0.4 mL/min and 45 ºC in temperature. A mass spectrometer operated in selected reaction monitoring mode to monitor the deprotonated molecular ion of artepillin C (m/z 299) > fragment ion (m/z 200.12). Several parameters such as specificity, linearity, limit of detection (LOD), limit of quantitation (LOQ), precision, accuracy, and robustness were determined.

Results:

The method was linear in the 50 ­ 400 µg/mL range (r2 = 0.9906), showing LOD = 10.79 µg/mL and LOQ = 32.70 µg/mL with satisfactory intra-day and inter-day precision with relative standard deviation (RSD %) of 1.9% and 3.4%, respectively. The accuracy showed recovery of 93-104%, the method was robust and artepillin C was quantified in green propolis at 6.51%.

Conclusions:

The proposed method showed advantages in comparison with other methods, such as short analysis time and high selectivity for artepillin C.
Palavras-chave
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS País/Região como assunto: America do sul / Brasil Idioma: En Revista: Rev. ciênc. farm. básica apl Assunto da revista: FARMACOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil
Texto completo: 1 Coleções: 01-internacional Base de dados: LILACS País/Região como assunto: America do sul / Brasil Idioma: En Revista: Rev. ciênc. farm. básica apl Assunto da revista: FARMACOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil