Nonlinear models for soil moisture sensor calibration in tropical mountainous soils
Silva, Bárbara Pereira Christofaro; Tassinari, Diego; Silva, Marx Leandro Naves; Silva, Bruno Montoani; Curi, Nilton; Rocha, Humberto Ribeiro da.
Afiliação
  • Silva, Bárbara Pereira Christofaro; Instituto Federal de Educação, Ciência e Tecnologia do Pará. Óbidos. BR
  • Tassinari, Diego; Universidade Federal de Lavras. Depto. de Ciência do Solo. Lavras. BR
  • Silva, Marx Leandro Naves; Universidade Federal de Lavras. Depto. de Ciência do Solo. Lavras. BR
  • Silva, Bruno Montoani; Universidade Federal de Lavras. Depto. de Ciência do Solo. Lavras. BR
  • Curi, Nilton; Universidade Federal de Lavras. Depto. de Ciência do Solo. Lavras. BR
  • Rocha, Humberto Ribeiro da; Universidade de São Paulo. IAG. Depto. de Ciências Atmosféricas. São Paulo. BR
Sci. agric ; 79(4): e20200253, 2022. tab, graf
Article em En | VETINDEX | ID: biblio-1290217
Biblioteca responsável: BR68.1
ABSTRACT
Electromagnetic sensors are widely used to monitor soil water content (θ); however, site-specific calibrations are necessary for accurate measurements. This study compares regression models used for calibration of soil moisture sensors and investigates the relation between soil attributes and the adjusted parameters of the specific calibration equations. Undisturbed soil samples were collected in the A and B horizons of two Ultisols and two Inceptisols from the Mantiqueira Range in Southeastern Brazil. After saturation, the Theta Probe ML2X was used to obtain the soil dielectric constant (ε). Several readings were made, ranging from saturation to oven-dry. After each reading, the samples were weighted to calculate θ (m³ m-³). Fourteen regression models (linear, linearized, and nonlinear) were adjusted to the calibration data and checked for their residue distribution. Only the exponential model with three parameters met the regression assumptions regarding residue distribution. The stepwise regression was used to obtain multiple linear equations to estimate the adjusted parameters of the calibration model from soil attributes, with silt and clay contents providing the best relations. Both the specific and the general calibrations performed well, with RMSE values of 0.02 and 0.03 m³ m-³, respectively. Manufacturer calibration and equations from the literature were much less accurate, reinforcing the need to develop specific calibrations.