Your browser doesn't support javascript.
loading
Independent mitral valve predictors of restenosis after percutaneous mitral balloon commissurotomy in a large, consecutive cohort followed for more than two decades
Ferreira-Neto, Alfredo Nunes; Costa Jr, J. Ribamar; Braga, Sergio; Ramos, Auristela I. O; Meneghelo, Zilda; Maldonado, Mercedes; Siqueira, Dimytri; Esteves, Cesar; Sousa, Amanda; Abizaid, Alexandre.
Afiliação
  • Ferreira-Neto, Alfredo Nunes; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Costa Jr, J. Ribamar; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Braga, Sergio; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Ramos, Auristela I. O; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Meneghelo, Zilda; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Maldonado, Mercedes; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Siqueira, Dimytri; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Esteves, Cesar; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Sousa, Amanda; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
  • Abizaid, Alexandre; Instituto Dante Pazzanese de Cardiologia. São Paulo. BR
Rev. arg. cardioangiol. interv ; 12(3): 26-27, jul-sept., 2021.
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1292080
Biblioteca responsável: BR79.1
ABSTRACT

AIMS:

the objective of this study was to enlight risk factors of mitral valvular restenosis in a significant number of patients submitted to percutaneous mitral balloon commissurotomy for the treatment of mitral stenosis (ms), particularly when secondary to rheumatic heart disease. METHODS AND

RESULTS:

this study reports the vast experience of a single center high volume tertiary institution where 1,794 consecutive patients were treated with PMBC between 1987 and 2011. the primary endpoint was to determine the independent predictors of this untoward event, defined as loss of over 50% of the original increase in maximum valve area (mva) or mva < 1.5 cm2. mitral valve restenosis was observed in 26% of the cases (n=483). average population age was 36 years old, with most patients being female (87%). mean follow up duration was 4.8 years. at multivariate analysis independent pre-procedural predictors of restenosis were left atrial diameter (hr 1.03, 95% ci 1.01-1.04, p<0.01). pre procedure maximum gradient (hr 1.01, 95% ci 1.00-1.03, p=0.02) and higher wilkins scores (hr 1.37, 95% ci 1.13-1.66, p<0.01).

CONCLUSIONS:

In the very long term follow-up, mitral valve restenosis was observed in a quarter of the population undergoing PMBC. Preprocedure echocardiographic findings, including left atrial diameter, maximum valve gradient and high wilkins scores were found to be the only indepen dent predictors of this deleterious event.
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Brasil Base de dados: CONASS / Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Angioplastia com Balão / Valva Mitral / Estenose da Valva Mitral Tipo de estudo: Estudo prognóstico / Fatores de risco Idioma: Inglês Revista: Rev. arg. cardioangiol. interv Ano de publicação: 2021 Tipo de documento: Artigo / Congresso e conferência Instituição/País de afiliação: Instituto Dante Pazzanese de Cardiologia/BR

Texto completo: Disponível Coleções: Bases de dados nacionais / Brasil Base de dados: CONASS / Sec. Est. Saúde SP / SESSP-IDPCPROD Assunto principal: Angioplastia com Balão / Valva Mitral / Estenose da Valva Mitral Tipo de estudo: Estudo prognóstico / Fatores de risco Idioma: Inglês Revista: Rev. arg. cardioangiol. interv Ano de publicação: 2021 Tipo de documento: Artigo / Congresso e conferência Instituição/País de afiliação: Instituto Dante Pazzanese de Cardiologia/BR
...