Capacidad de sellado apical entre dos técnicas de obturación con instrumentos rotatorios fracturados en tercio apical / Apical sealing capacity between two obturation techniques with rotary instruments broken in third apical
Rev. ADM
; 79(3): 146-151, mayo-jun. 2022. ilus, tab
Artigo
em Espanhol
| LILACS
| ID: biblio-1378372
Biblioteca responsável:
AR29.1
RESUMEN
Introducción:
La finalidad del tratamiento de conductos es conseguir la máxima desinfección, conformación y sellado tridimensional.Objetivo:
Comparar la capacidad del sellado apical entre dos técnicas de obturación en conductos mesiales de molares inferiores con limas fracturadas en tercio apical. Material ymétodos:
Se utilizaron 60 raíces mesiales de molares inferiores, instrumentados con Protaper Universal, se desgastó 4 milímetros la parte activa del instrumento y se fracturó intencionalmente en tercio apical. Se formaron dos grupos de 30 raíces mesiales (n = 30) cada uno y se utilizaron dos técnicas de obturación grupo 1 condensación lateral clásica y grupo 2 Obtura II. Las muestras se sumergieron en tubos de ensayo y en su interior contenían 5 mL de tinta china, se diafanizaron y observaron con un microscopio estereoscópico (LEICA, EZ4D) a 35x para medir la penetración de tinta china dentro del conducto radicular.Resultados:
Se encontró una mayor microfiltración apical con suficiente evidencia estadística en el grupo de Obtura II comparado con el grupo de condensación lateral clásica (p < 0.002).Conclusiones:
Ambos grupos presentaron microfiltración apical; sin embargo, en el grupo que se utilizó el sistema de obturación termoplastificada Obtura II se detectó mayor filtración apical comparada con el grupo de condensación lateral clásica (AU)ABSTRACT
Introduction:
The purpose of root canal treatment is to achieve maximum disinfection, shaping and three-dimensional sealing.Objective:
To compare the apical sealing capacity between two obturation techniques in mesial canals of mandibular molars with broken files in the apical third. Material andmethods:
60 mesial roots of lower molars were used, instrumented with Protaper Universal, the active part of the instrument was worn by 4 millimeters and it was intentionally broken in the apical third. Two groups of 30 mesial roots (n = 30) each were formed and two filling techniques were used group 1 classic lateral condensation and group 2 Obtura II. The samples were immersed in test tubes and contained 5 mL of Chinese ink inside, they were clear and observed with a stereomicroscope (LEICA, EZ4D) at 35x to measure the penetration of Chinese ink into the root canal.Results:
A higher apical microfiltration with sufficient statistical evidence was found in the Obtura II group compared to the classic lateral condensation group (p < 0.002).Conclusions:
Both groups presented apical microfiltration, however, in the group that used the Obtura II thermoplastic obturation system, greater apical filtration was detected compared to the classic lateral condensation group (AU)
C - Todos os direitos reservados
Assuntos
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Base de dados:
LILACS
Assunto principal:
Obturação do Canal Radicular
/
Equipamentos Odontológicos de Alta Rotação
/
Infiltração Dentária
Tipo de estudo:
Estudo observacional
/
Estudo de prevalência
/
Fatores de risco
Idioma:
Espanhol
Revista:
Rev. ADM
Assunto da revista:
Odontologia
/
Ortodontia
Ano de publicação:
2022
Tipo de documento:
Artigo
País de afiliação:
México
Instituição/País de afiliação:
Universidad Autónoma de Tamaulipas/MX