RESUMEN
Introducción:
la adaptación marginal e interna de nuestras restauraciones fabricadas por fundición sistemas de fresado y sinterización láser es uno de los factores clínicos más importantes para el éxito de las prótesis fijas, previniendo el riesgo de microfiltración y enfermedad periodontal.Objetivo:
evaluar la adaptación marginal e interna de cofias metálicas en aleación Cr-Co confeccionadas por técnicas convencionales, CAD/ CAM de fresado y sinterizado por láser. Material ymétodos:
estudio de tipo experimental, comparativo e in vitro. Se imprimió un modelo maestro en Cr-Co, proveniente del escaneo de un premolar preparado para corona completa, sobre el cual se diseñaron 30 cofias divididas en tres grupos el primero que corresponde al grupo cofias fundidas fresadas en disco de cera A (A = 10), el segundo grupo cofias fresadas en disco de metal presinterizado B (B = 10) y el tercer grupo cofias impresas por sinterización láser C (C = 10). Se empleó la réplica de silicona, colocando silicona al interior de cada cofia, sobre el modelo maestro, simulando al cemento, mediante una máquina de ensayo universal se realizó una compresión de 50 N. Luego de retirar cada cofia se rellenaron con silicona pesada de adición, obteniendo una réplica de silicona. Se efectuaron dos cortes transversales en sentido vestíbulolingual y mesiodistal. Se observó el espesor de silicona VPS (vinil poliéter silicona) mediante un estereomicroscopio (Nikon SMZ745T), obteniendo valores en micrómetros. Para el análisis estadístico se utilizó el software SPSS 25 con el fin de realizar la prueba de normalidad y ANOVA de dos vías bajo un nivel de confianza del 95%.Resultados:
el menor gap lo obtuvo el grupo de fresadas, seguido de las impresas y por último las fundidas por métodos convencionales. ANOVA de dos vías reveló diferencias estadísticamente significativas entre los tres grupos (p < 0.0001).Conclusiones:
se encontró que el gap varía con cada método de fabricación, la técnica convencional de fundido mostró un mayor gap, ninguna excediendo el rango clínicamente aceptable (AU)ABSTRACT
Introduction:
the marginal and internal adaptation of our restorations manufactured by casting, milling systems and laser sintering is one of the most important clinical factors for the success of fixed prostheses, preventing the risk of microleakage and periodontal disease.Objective:
evaluate the marginal and internal adaptation of metal copings in Cr-Co alloy made by conventional techniques, CAD/CAM milling and laser sintering. Material andmethods:
an experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown. An experimental, comparative and in vitro study, a Cr-Co master model was printed from the scan of a premolar prepared for a full crown, on which 30 caps divided into three groups were designed; the first group corresponds to the cast copings milled on a wax disc A (A = 10), the second group milled copings on a presintered metal disc B (B = 10) and the third group printed by laser sintering copings C (C = 10). The silicone replica was used, placing silicone inside each coping, on the master model, simulating cement, using a universal testing machine, a 50 N compression was performed. After removing each coping, they were filled with heavy addition silicone, obtaining a silicone replica. Two cross-sections were made in the buccolingual and mesiodistal direction., observing the thickness of the VPS (vinyl polyeter silicone) silicone using a stereomicroscope (Nikon SMZ745T), obtaining values in micrometers. For the statistical analysis, the SPSS 25 software was used in order to perform the normality and two-way ANOVA tests under a 95% confidence level.Results:
the smallest gap was obtained by the milled group, followed by the printed ones and finally those cast by conventional methods. Two-way ANOVA revealed statistically significant differences between the three groups (p < 0.0001).Conclusions:
the gap was found to vary with each fabrication method, the conventional casting technique showed a larger gap, none exceeding the clinically acceptable range (AU)
C - All Rights Reserved
AssuntosPalavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Ligas de Cromo
/
Desenho Assistido por Computador
/
Adaptação Marginal Dentária
/
Coroas
/
Lasers
Tipo de estudo:
Prognostic_studies
Idioma:
Es
Revista:
Rev. ADM
Assunto da revista:
ODONTOLOGIA
/
ORTODONTIA
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
Equador
País de publicação:
México