Exactitud del Xiaomi Mi Band 4 para contabilizar pasos en adultos con enfermedades respiratorias crónicas. Estudio de concordancia / Accuracy of the Xiaomi Mi Band 4 for Steps Counting in Adults with Chronic Respiratory Diseases. Agreement Study
Respirar (Ciudad Autón. B. Aires)
; 16(2): 101-111, Junio 2024.
Article
em Es
| LILACS, UNISALUD, BINACIS
| ID: biblio-1556075
Biblioteca responsável:
AR41.1
RESUMEN
Introducción:
El Xiaomi Mi Band 4 (XMB4) demostró ser exacto para medir pasos en sujetos sanos, pero no ha sido estudiado en pacientes con enfermedades respiratorias crónicas (ERC).Objetivos:
Evaluar la exactitud del XMB4 para cuantificar pasos caminados en pacientes con ERC. Secundariamente, evaluar su viabilidad y usabilidad.Material ymétodos:
Estudio de concordancia contrastando los datos del XMB4 con la video-filmación (prueba de referencia). Fueron incluidos mayores de 18 años con diversas ERC y excluidos aquellos con deterioro cognitivo, limitaciones osteoarticulares y/o cardiovasculares que impedían la marcha. Realizamos un muestreo por conveniencia de pacientes que participaban de un programa de rehabilitación pulmonar.Las variables estudiadas incluyeron número de pasos, distancia y tiempo caminado, velocidad de la marcha, viabilidad y usabilidad. Cada participante realizó cinco caminatas (5, 10 y 30 metros, y 5 minutos a ritmo lento y rápido). Para testear la equivalencia estadística, necesitamos incluir 33 pacientes y utilizamos el método de intervalo de confianza con una zona de equivalencia de ±15%.Resultados:
Fueron incluidos 33 pacientes, 64% mujeres, con una mediana (P25-75) de edad de 64,9 (55,8 a 70,2) años. Los pasos registrados por el XMB4 fueron equivalentes a los de la video-filmación en las diferentes caminatas, excepto en la de 5 metros. Los pasos fueron subestimados con un error de medición menor al 15%.Conclusiones:
El XMB4 tiene una exactitud aceptable para medir pasos en pacientes con ERC excepto en caminatas muy cortas, es viable y fácil de usarABSTRACT
Introduction:
Xiaomi Mi Band 4 (XMB4) has been shown to be accurate to measure steps in healthy subjects, but has not been studied in patients with chronic respiratory diseases (CRD).Objectives:
To evaluate the accuracy of the XMB4 to quantify steps walked in patients with CRD. Secondarily, evaluate its feasibility and usability.Materials andmethods:
Agreement study compared the XMB4 data with the video (reference test). Adults aged 18 years or older with various CRD were included and those with cognitive impairment, osteoarticular and/or cardiovascular limitations that prevented walking were excluded. We conducted a convenience sampling of patients participating in a pulmonary rehabilitation program. Outcome measures studied included number of steps, distance and time walked, walking speed, feasibility and usability. Each participant performed five walks (5, 10 and 30 meters, and 5 minutes at a slow and fast pace).To test statistical equivalence we need to include 33 patients and use the confidence interval method with an equivalence zone of ±15%.Results:
33 patients were included, 64% women, with a median (P25-75) age of 64.9 (55.8 to 70.2) years. The steps recorded by the XMB4 were equivalent to those of the video in the different walks, except for the 5-meter walk. The steps were underestimated with a measurement error of less than 15%.Conclusions:
XMB4 has acceptable accuracy for measuring steps in patients with CRD except for very short walks, it is feasible and easy to us.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BINACIS
/
LILACS
/
UNISALUD
Assunto principal:
Doenças Respiratórias
/
Teste de Caminhada
/
Monitores de Aptidão Física
Limite:
Aged
/
Female
/
Humans
/
Male
País/Região como assunto:
America do sul
/
Argentina
Idioma:
Es
Revista:
Respirar (Ciudad Autón. B. Aires)
Assunto da revista:
Farmacologia
/
Teraputica
/
Toxicologia
/
T¢rax
Ano de publicação:
2024
Tipo de documento:
Article
País de afiliação:
Argentina
/
Espanha
País de publicação:
Argentina