Cirurgia para correção de pectus escavatum utilizando tela de márlex para sustentação / Surgery for pectus escavatum correction with marlex mesh as sustein
Rev. AMRIGS
; 52(1): 34-37, jan.-mar. 2008. ilus
Article
em Pt
| LILACS
| ID: biblio-859526
Biblioteca responsável:
BR18.1
RESUMO
Objetivos:
Computar o resultado obtido em 24 pacientes submetidos à correção cirúrgica de pectus escavatum(PEX) pela técnica convencional no Serviço de Cirurgia Torácica da Universidade Luterana do Brasil.Método:
Os prontuários de 24 pacientes, em sua maioria homens jovens, submetidos à correção cirúrgica de PEX no período de 5 anos foram revisados. A indicação cirúrgica foi o motivo estético que levou o paciente a consultar. A técnica cirúrgica consistiu em incisão transversal, retirada de 5 cartilagens bilateralmente, fratura da tábua anterior do esterno, suporte com tela de márlex e fechamento. Indicação, técnica, complicações e resultados foram computados. O tempo médio de internação e retorno às atividades foram de 3 e 7 dias, respectivamente.Resultados:
Dos 24 pacientes, 23 tinham PEX simétrico e 1 era um caso de reoperação. Houve 3 complica- ções 1 hemotórax residual, um hematoma de subcutâneo e, em 1 caso, houve recidiva após 5 anos, o qual teve de ser reoperado. O resultado final, do ponto de vista de satisfa- ção, foi considerado pelos 24 pacientes ótimo ou muito bom.Conclusão:
A cirurgia para correção de PEX utilizando a técnica convencional apresenta resultados satisfatórios (AU)ABSTRACT
Objectives:
Data analysis of 24 patients submitted to surgical Pectus Escavatum (PEX) correction through the conventional procedure at the ULBRA Thoracic Surgery Service.Methods:
The records of 24 patients submitted to surgical correction of PEX were revised through a 5-year period. Majority of them were male and young. The procedure was carried on through a transversal incision, bilateral withdrawal of 5 cartilages, fracture of the anterior board of the sternum, sustained with marlex mesh and closing. Indication, complications and results were reviewed. The mean hospitalization time was 3 days. The mean time to complete recovery and return to the usual activities was 7 days.Results:
Twenty three patients had a symmetric PEX and 1 was a re-intervention. There were 3 patients with complications, a residual hemothorax, a subcutaneous hematoma and a recurrence after 5 years, which was re-operated. The patient satisfaction on the final results was graded in excellent or very good.Conclusion:
The surgery for correction of PEX using the conventional procedure is safe and effective (AU)Palavras-chave
Buscar no Google
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Telas Cirúrgicas
/
Tórax em Funil
Tipo de estudo:
Observational_studies
Limite:
Adolescent
/
Adult
/
Child
/
Female
/
Humans
/
Male
Idioma:
Pt
Revista:
Rev. AMRIGS
Assunto da revista:
MEDICINA
Ano de publicação:
2008
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil