Transcatheter aortic valve replacement: the experience of one brazilian health care center
Rev. bras. cir. cardiovasc
; 33(1): 1-7, Jan.-Feb. 2018. tab, graf
Artigo
em Inglês
| LILACS
| ID: biblio-897979
Biblioteca responsável:
BR1.1
ABSTRACT
Abstract Objective:
Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation pre-and post- transcatheter aortic valve replacement, and the occurrence of complications throughout a 4-year follow-up period.Methods:
This prospective cohort, nestled to a multicenter study (Registro Brasileiro de Implante de Bioprótese por Cateter), describes the experience of a public tertiary center in transcatheter aortic valve replacement. All patients who underwent this procedure between October 2011 and February 2016 were included.Results:
Fifty-eight patients underwent transcatheter aortic valve replacement. The 30-day all-cause mortality was 5.2% (n=3) and after 1 year was 17.2% (n=10). A significant improvement in New York Heart Association functional classification was observed when comparing pre-and post- transcatheter aortic valve replacement (III or IV 84.4% versus 5.8%; P<0.001). A decline in peak was observed (P<0.001) and mean (P<0.001) systolic transaortic gradient. The results of peak and mean post-implant transaortic gradient were sustained after one year (P=0.29 and P=0.36, respectively). Left ventricular ejection fraction did not change significantly during follow-up (P=0.41). The most frequent complications were bleeding (28.9%), the need for permanent pacemaker (27.6%) and acute renal injury (20.6%).Conclusion:
Mortality and complications in this study were consistent with worldwide experience. Transcatheter aortic valve replacement had positive clinical and hemodynamic results, when comparing pre-and post-procedure, and the hemodynamic profile of the prosthesis was sustained throughout follow-up.
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Contexto em Saúde:
ODS3 - Meta 3.4 Reduzir as mortes prematuras devido doenças não transmissíveis
Problema de saúde:
Doença Cardiovascular
Base de dados:
LILACS
Assunto principal:
Estenose da Valva Aórtica
/
Substituição da Valva Aórtica Transcateter
Tipo de estudo:
Ensaio clínico controlado
/
Estudo de etiologia
/
Estudo observacional
/
Fatores de risco
Limite:
Idoso
/
Idoso, 80 anos ou mais
/
Feminino
/
Humanos
/
Masculino
País/Região como assunto:
América do Sul
/
Brasil
Idioma:
Inglês
Revista:
Rev. bras. cir. cardiovasc
Assunto da revista:
Cardiologia
/
CIRURGIA GERAL
Ano de publicação:
2018
Tipo de documento:
Artigo
País de afiliação:
Brasil
Instituição/País de afiliação:
Instituto Nacional de Cardiologia/BR