Your browser doesn't support javascript.
loading
La Mínima Incisión en la cirugía de catarata pediátrica / Minor Incision pediatric cataract surgery
Machin Pérez, Jacqueline; Fernández Domínguez, Tania M; Chang Velázquez, Josefina; Pineda Durán, Grester A; Pérez Aguedo, Daniuby; Escalona Almarales, Yadelín.
Afiliação
  • Machin Pérez, Jacqueline; Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja. Holguín. CU
  • Fernández Domínguez, Tania M; Hospital Clínico Quirúrgico Lucía Íñiguez Landín. Holguín. CU
  • Chang Velázquez, Josefina; Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja. Holguín. CU
  • Pineda Durán, Grester A; Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja. Holguín. CU
  • Pérez Aguedo, Daniuby; Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja. Holguín. CU
  • Escalona Almarales, Yadelín; Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja. Holguín. CU
CCH, Correo cient. Holguín ; 22(4): 618-633, oct.-dic. 2018. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-974516
Biblioteca responsável: CU1.1
RESUMEN

Introducción:

las cataratas congénitas e infantiles constituyen una amenaza para el desarrollo visual en los niños, pues inhiben o detienen potencialmente su maduración, unido a la complejidad de su tratamiento.

Objetivo:

evaluar los resultados visuales y anatómicos de la cirugía de catarata infantil con el uso de la incisión corneal pequeña autosellante.

Método:

se realizó un estudio transversal, cuyo universo estuvo constituido por 19 niños (24 ojos) con catarata congénita e infantil, intervenidos quirúrgicamente en el Hospital Pediátrico de Holguín en 2016 y 2017. Se evaluaron las variables edad, sexo, etiología, agudeza visual pre y postoperatoria a los 3 meses, técnica quirúrgica empleada, astigmatismo inducido, conservación de la transparencia y curvatura corneal, así como complicaciones.

Resultados:

predominó el grupo de edad de 3 a 8 años con el 47,4%, y el sexo masculino, con el 79%, y la etiología congénita ascendió hasta el 50%. La agudeza visual preoperatoria entre percepción luminosa a 0,1 se presentó en el 50%. En la postoperatoria del 62,5% de los casos se obtuvo entre 0,7 a 1,0. La técnica quirúrgica empleada fue la incisión corneal pequeña autosellante, en el 75%, y el astigmatismo inducido fue bajo, menor de 1 D. La transparencia corneal se conservó en el 100%, y en el 62,5% la curvatura corneal tuvo variaciones mínimas (≤0,50 D). Las complicaciones más frecuentes fueron opacidad de la cápsula posterior con 50% y uveítis anterior con el 37,5%.

Conclusiones:

el uso de la incisión corneal pequeña autosellante en la cirugía de catarata infantil garantiza buenos resultados visuales y anatómicos.
ABSTRACT

Introduction:

congenital and infant cataracts are a threat for children visual development because this can mainly be inhibited or stopped and it also requires a complicated treatment.

Objective:

to evaluate anatomic and visual results of infant cataracts surgeries by self-sealant corneal incision.

Method:

a transversal study which universe was composed by 19 children (24 eyes) suffering from congenital or infants cataracts, who were operated at the Pediatric Hospital of Holguín, during 2016 to 2017, was carried out. Some variables like age, sex, etiology, pre and postsurgical visual sharpness in the first 3 months, surgical techniques, induced astigmatism, transparency preservation corneal curve and possible complications, were evaluated.

Results:

ages from 3 to 8 years prevailed up to 47.4%, as well as males with 79% and congenital etiology with a 50%. Pre-surgical visual sharpness was in the range of PL- 0.1 representing the 50%, while post- surgical was between 0.7- 1.0 in 62.5% of the cases. Surgical technique was the self-sealant small incision in 75%. Induced astigmatism was low, less than 1D. Corneal transparency was obtained 100%, and the corneal curvature had minor variations (≤0.50D) in 62.5% of the cases. Most frequent complications were posterior capsule dullness (50%) and the anterior uveitis (37.5%).

Conclusions:

the use of the small self-sealant corneal incision in the infant cataracts surgery guarantees good anatomic and visual outcomes.

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo observacional / Estudo de prevalência Idioma: Espanhol Revista: CCH, Correo cient. Holguín Assunto da revista: Medicina Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Hospital Clínico Quirúrgico Lucía Íñiguez Landín/CU / Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja/CU
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Tipo de estudo: Estudo observacional / Estudo de prevalência Idioma: Espanhol Revista: CCH, Correo cient. Holguín Assunto da revista: Medicina Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Cuba Instituição/País de afiliação: Hospital Clínico Quirúrgico Lucía Íñiguez Landín/CU / Hospital Pediátrico Provincial Octavio de la Concepción y de la Pedraja/CU
...