Your browser doesn't support javascript.
loading
Ventilación de alta frecuencia: experiencia inicial en la Unidad de Cuidados Intensivos del Hospital Pediátrico Baca Ortíz de Quito-Ecuador / High frequency ventilation: initial experience in the Unit of Intensive Care of the Hospital Pediatric Baca Ortíz of Quito-Ecuador
Martínez, Jenny; Paredes, Patricio; Silva, Miguel; Montenegro, Carmita.
Afiliação
  • Martínez, Jenny; Hospital Pediátrico Baca Ortíz. Unidad de Cuidados Intensivos Pediátricos. Quito. EC
  • Paredes, Patricio; Hospital Pediátrico Baca Ortíz. Unidad de Cuidados Intensivos Pediátricos. Quito. EC
  • Silva, Miguel; Hospital Pediátrico Baca Ortíz. Unidad de Cuidados Intensivos Pediátricos. Quito. EC
  • Montenegro, Carmita; Hospital Pediátrico Baca Ortíz. Unidad de Cuidados Intensivos Pediátricos. Quito. EC
VozAndes ; 27(1): 45-48, 2016.
Artigo em Espanhol | LILACS | ID: biblio-999568
Biblioteca responsável: EC147.1
RESUMEN
La ventilación mecánica es necesaria para asegurar un adecuado intercambio gaseoso en la insufciencia respiratoria, especialmente en el Síndrome de Distress Respiratorio Agudo (SDRA), pero puede inducir daño pulmonar y contribuir al desarrollo de disfunción multiorgánica. Los cambios cíclicos de volumen pulmonar generan mayor distensión y/o colapso de áreas pulmonares, lo que sería un factor determinante para un eventual daño [1­3]. Es por ello que las estrategias ventilatorias protectoras buscan el empleo de bajos volúmenes corrientes, generalmente asociado a PEEP elevado e hipercapnia permisiva, perflándose en forma promisoria en pacientes que padecen dicha patología [4, 5]. Pero en ocasiones, ante el fracaso de esta modalidad terapéutica, cada vez más se ha desarrollado en las Unidades de Cuidados Intensivos Pediátricos el uso de la ventilación de alta frecuencia oscilatoria (VAFO). Así, ventilando por medio de la VAFO en una zona de seguridad situada entre los puntos de inflexión superior e inferior de la curva de presión volumen estática, se evitan los ciclos de colapso pulmonar seguidos de sobredistensión pulmonar
ABSTRACT
Mechanical ventilation is necessary to ensure adequate gaseous exchange in respiratory insufficiency, especially in Acute Respiratory Distress Syndrome (ARDS), but it can induce lung damage and contribute to the development of multi-organ dysfunction. Cyclic changes in lung volume generate more distension and / or collapse of pulmonary areas, which would be a determining factor for eventual damage [1-3]. That is why the ventilatory strategies Protectors seek the use of low running volumes, generally associated with elevated PEEP and permissive hypercapnia, profiling itself in a promising way in patients suffering from this pathology [4, 5]. But sometimes, given the failure of this modality therapeutic, has increasingly been developed in Units of Pediatric Intensive Care the use of high ventilation oscillatory frequency (HFOV). Thus, ventilating through HFOV in a safety zone located between the points of superior in fl ection and lower of the static volume pressure curve, cycle cycles are avoided Pulmonary collapse followed by pulmonary overdistension
Assuntos

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ventilação de Alta Frequência / Oxigenação / Criança Limite: Humanos País/Região como assunto: América do Sul / Equador Idioma: Espanhol Revista: VozAndes Assunto da revista: Medicina Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Equador Instituição/País de afiliação: Hospital Pediátrico Baca Ortíz/EC
Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Ventilação de Alta Frequência / Oxigenação / Criança Limite: Humanos País/Região como assunto: América do Sul / Equador Idioma: Espanhol Revista: VozAndes Assunto da revista: Medicina Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Equador Instituição/País de afiliação: Hospital Pediátrico Baca Ortíz/EC
...