Your browser doesn't support javascript.
loading
Seguimiento a cuatro años de pacientes con stent / Firebird liberador de sirolimus en Cuba
Lopez Perez, Jorge E; Filgueiras Frias, Enrique; Ariche Aportela, Ronald; Llerena Rojas, Lorenzo; Lopez Ferrero, Leonardo; Obregon Santos, Angel Gaspar; Mendez Peralta, Tomas.
Afiliação
  • Lopez Perez, Jorge E; s.af
  • Filgueiras Frias, Enrique; s.af
  • Ariche Aportela, Ronald; s.af
  • Llerena Rojas, Lorenzo; s.af
  • Lopez Ferrero, Leonardo; s.af
  • Obregon Santos, Angel Gaspar; s.af
  • Mendez Peralta, Tomas; s.af
Rev Fed Arg Cardiol ; 39(2)2010. ilus, graf
Article em Es | CUMED | ID: cum-43672
Biblioteca responsável: CU1.1
RESUMEN
Se realizó un estudio descriptivo, longitudinal prospectivo, multicéntrico nacional, en Cuba, con la participación del Instituto de Cardiología y Cirugía Cardiovascular, el Centro de Investigaciones Médico Quirúrgicas y el Hospital Hermanos Ameijeiras. El objetivo fue caracterizar el seguimiento clínico y angiográfico a largo plazo de los pacientes a los que se implantó stent Firebird® liberador de sirolimus (rapamycin), de fabricación china, en el período comprendido entre enero de 2006 y agosto de 2008. Material y método: se implantaron 69 endoprótesis en 52 pacientes. Se utilizaron distribuciones de frecuencia, medidas de tendencia central, cálculos porcentuales, odds ratio y chi cuadrado, así como curva de Kaplan-Meier. Resultados: a los 8 meses se documentó reestenosis del stent en el 7,7 por ciento de los pacientes reestudiados. La mortalidad y la tasa de reestenosis en la población estudiada fueron realmente bajas. No hubo trombosis tardías ni muy tardías del stent. Las oclusiones totales crónicas y las nuevas lesiones con criterios de revascularización incrementaron el riesgo de eventos cardiovasculares mayores. Conclusiones: el uso del stent Firebird® liberador de sirolimus en la población estudiada fue seguro, con una supervivencia libre de eventos mayores cardiovasculares significativamente importante(AU)
ABSTRACT
This is a descriptive, longitudinal prospective, a Cuban multicenter study with the participation of the Institute of Cardiology and Cardiovascular Surgery, the Center of Investigations Surgical Medical, and the Clinical Surgical Hospital Hermanos Ameijeiras.The aim of this research was to characterize the clinical and angiographic monitoring patients who were implanted with the chinese Firebird® drug-eluting stent (rapamycin). Material and method. A total of 52 patients were implanted with 69 of these stents, from January 2006 to August 2008. In order to study the survival analysis, frequency distributions, central tendencies, percentage calculations, odds ratios, chi-square, and the Kaplan-Meier curve were used. Results. After eight months, 7.7 percent of the patients were documented with stent restenosis. Mortality and restenosis rates were low. This research did not find late and very late thrombosis. The chronic total occlusions and the new lesions with revascularization approaches increased the risk of major cardiovascular events.Conclusions. The use in Cuba of the Firebird® sirolimus-eluting stent was safe, with a MACE free survival significantly high(AU)
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Doenças Cardiovasculares / Cuba / Stents Farmacológicos Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Caribe / Cuba Idioma: Es Revista: Rev Fed Arg Cardiol Ano de publicação: 2010 Tipo de documento: Article
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Doenças Cardiovasculares / Cuba / Stents Farmacológicos Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Caribe / Cuba Idioma: Es Revista: Rev Fed Arg Cardiol Ano de publicação: 2010 Tipo de documento: Article