Your browser doesn't support javascript.
loading
Variación del endotelio corneal en pacientes operados de alta miopía con implante de lentes fáquicas / Variation of the corneal endothelium in patients operated on from high myopia, with phakic lens implantation
López Hernández, Silvia María; Rodriguez Rivero, Darlen; González Duque, Yamile; Martín Perera, Yoanner; Castro Cárdenas, Karyna.
Afiliação
  • López Hernández, Silvia María; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. Cuba
  • Rodriguez Rivero, Darlen; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. Cuba
  • González Duque, Yamile; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. Cuba
  • Martín Perera, Yoanner; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. Cuba
  • Castro Cárdenas, Karyna; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. Cuba
Rev. cuba. oftalmol ; 26(3): 360-368, sept.-dic. 2013.
Article em Es | CUMED | ID: cum-60391
Biblioteca responsável: CU1.1
Localização: CU1.1
RESUMEN
Objetivo: determinar la variación que evidencia el endotelio corneal, en pacientes operados de alta miopía con la utilización de lentes intraoculares fáquicas de cámara anterior con soporte iridiano. Método: se realizó un estudio longitudinal, prospectivo y descriptivo en una muestra conformada por 26 ojos de 15 pacientes, operados de alta miopía con la utilización de lentes intraoculares fáquicas Artisan y Artiflex de cámara anterior con soporte iridiano, que se atendieron en el Servicio de Córnea y Cirugía Refractiva del Instituto Cubano de Oftalmología Ramón Pando Ferrer de septiembre de 2009 a mayo de 2010. Resultados: se evidenció una pérdida celular endotelial posterior a la cirugía seis meses de 6,9 por ciento. En el posoperatorio la hexagonalidad y el coeficiente de variación disminuyeron, mientras que la paquimetría no mostró diferencias significativas. Conclusiones: en el presente estudio se observó la presencia de un daño mínimo en el endotelio corneal con el uso de lentes fáquicas de cámara anterior, en la corrección quirúrgica de las altas miópias(AU)
ABSTRACT
Objective: to determine the variation of the corneal endothelium in those patients operated on from high myopia, with the use of iris claw anterior chamber phakic intraocular lenses. Methods: a prospective, longitudinal and descriptive study was carried out in a sample of 26 eyes from 15 patients. They had been operated on from high myopia with the use of iris claw anterior chamber phakic intraocular lenses Artisan and Artiflex at the Cornea and Refractive Surgery Service of Ramon Pando Ferrer Cuban Institute of Ophthalmology from September 2009 through May 2010. Results: it was evinced that there was endothelial cell loss after surgery six months of 6.9 percent. In the postoperative phase, hexagonality and variation coefficient diminished whereas pakimetry did not show significant differences. Conclusions: the present study indicated the existence of minimal damage in the corneal endothelium with the use of the anterior chamber phakic lenses for the surgical correction of high myopias(AU)
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Endotélio Corneano / Implante de Lente Intraocular / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Observational_studies Limite: Female / Humans / Male Idioma: Es Revista: Rev. cuba. oftalmol Ano de publicação: 2013 Tipo de documento: Article
Texto completo: 1 Coleções: 06-national / CU Base de dados: CUMED Assunto principal: Endotélio Corneano / Implante de Lente Intraocular / Lentes Intraoculares Fácicas / Miopia Tipo de estudo: Observational_studies Limite: Female / Humans / Male Idioma: Es Revista: Rev. cuba. oftalmol Ano de publicação: 2013 Tipo de documento: Article