Your browser doesn't support javascript.
loading
Desarrollo de un modelo probabilístico de la actividad eléctrica cardíaca basado en un autómata celular / A probabilistic model of cardiac electrical activity based on a cellular automata system
Alonso Atienza, Felipe; Requena Carrión, Jesús; García Alberola, Arcadi; Rojo Álvarez, José L; Sánchez Muñoz, Juan J; Martínez Sánchez, Juan; Valdés Chávarri, Mariano.
Afiliação
  • Alonso Atienza, Felipe; Universidad Carlos III. Leganés. España
  • Requena Carrión, Jesús; Universidad Carlos III. Leganés. España
  • García Alberola, Arcadi; Hospital Universitario Virgen de la Arrixaca. Murcia. España
  • Rojo Álvarez, José L; Universidad Carlos III. Leganés. España
  • Sánchez Muñoz, Juan J; Hospital Universitario Virgen de la Arrixaca. Murcia. España
  • Martínez Sánchez, Juan; Hospital Universitario Virgen de la Arrixaca. Murcia. España
  • Valdés Chávarri, Mariano; Hospital Universitario Virgen de la Arrixaca. Murcia. España
Rev. esp. cardiol. (Ed. impr.) ; 58(1): 41-47, ene. 2005. graf
Artigo em Es | IBECS | ID: ibc-037145
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Introducción y objetivos. La utilización de modelos matemáticos de activación y propagación del impulso ha mejorado la comprensión de diversos mecanismos electrofisiológicos involucrados en la génesis de las arritmias. Las simulaciones más realistas se basan en los modelos de reacción-difusión e implican una carga computacional muy elevada. El objetivo del estudio es desarrollar un modelo de activación eléctrica cardíaca por ordenador que permita simular fenómenos electrofisiológicos complejos y que no requiera la carga computacional necesaria en otros modelos habitualmente empleados. Material y método. Se ha modelado el tejido cardíaco como un autómata celular, cada uno de cuyos elementos adopta estados discretos en función de su estado previo y del de las células vecinas siguiendo unas reglas sencillas. La activación se contempla como un proceso probabilístico y se ajusta mediante el fenómeno de restitución, mientras la repolarización se modela como un proceso determinista. Finalmente, las corrientes celulares se calculan utilizando un potencial de acción prototipo, lo que permite simular los electrogramas virtuales monopolares y bipolares en cualquier punto del espacio. Resultados. Se ha conseguido reproducir frentes planos de activación, propagación de un estímulo focal y reentradas estables e inestables en 2 dimensiones, con sus electrogramas correspondientes. El modelo es particularmente adecuado para simular los fenómenos asociados a la curvatura de los frentes, y permite reproducir la conducción fibrilatoria y los rotores estables en 2 y 3 dimensiones. Conclusiones. Aunque el modelo de autómata celular probabilístico desarrollado es sencillo y no requiere cargas computacionales elevadas, es capaz de simular de forma realista fenómenos complejos de gran interés en electrofisiología
ABSTRACT
Introduction and objectives. Mathematical models of cardiac electrical activity may help to elucidate the electrophysiological mechanisms involved in the genesis of arrhythmias. The most realistic simulations are based on reaction-diffusion models and involve a considerable computational burden. The aim of this study was to develop a computer model of cardiac electrical activity able to simulate complex electrophysiological phenomena but free of the large computational demands required by other commonly used models. Material and method. A cellular automata system was used to model the cardiac tissue. Each individual unit had several discrete states that changed according to simple rules as a function of the previous state and the state of the neighboring cells. Activation was considered as a probabilistic process and was adjusted using restitution curves. In contrast, repolarization was modeled as a deterministic phenomenon. Cell currents in the model were calculated with a prototypical action potential that allowed virtual monopolar and bipolar electrograms to be simulated at any point in space. Results. Reproducible flat activation fronts, propagation from a focal stimulus, and reentry processes that were stable and unstable in two dimensions (with their corresponding electrograms) were obtained. The model was particularly suitable for the simulation of the effects observed in curvilinear activation fronts. Fibrillatory conduction and stable rotors in two- and three-dimensional substrates were also obtained. Conclusions. The probabilistic cellular automata model was simple to implement and was not associated with a high computational burden. It provided a realistic simulation of complex phenomena of interest in electrophysiology
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Eletrofisiologia / Modelos Teóricos Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2005 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen de la Arrixaca/España / Universidad Carlos III/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Eletrofisiologia / Modelos Teóricos Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2005 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen de la Arrixaca/España / Universidad Carlos III/España
...