Your browser doesn't support javascript.
loading
Superficies bioactivas en implantología: una nueva perspectiva / Bioactive surfaces in implantology: a new perspective
Cutando, A; Gómez-Moreno, G; Arana, C.
Afiliação
  • Cutando, A; Universidad de Granada. Granada. España
  • Gómez-Moreno, G; Universidad de Granada. Granada. España
  • Arana, C; s.af
Av. periodoncia implantol. oral ; 19(supl.1): 43-50, feb. 2007.
Artigo em Es | IBECS | ID: ibc-053712
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Actualmente, tras años de investigación en implantología, en los cuales se han realizado muchos trabajos, en donde se han estudiado diferentes tipos de superficies de implantes, lisas y rugosas, en un intento de mejorar, tanto en el tiempo como en la calidad , la osteointegración, se ha concluido que los implantes de superficie rugosa con un intervalo de rugosidad entre 1,0-2,0 nm, son los que parecen dar una mejor respuesta ósea y mejores resultados clínicos, pero desde un punto de vista exclusivamente mecánico. Hoy en día las investigaciones se centran en el desarrollo de superficies denominadas bioactivas, las cuales son capaces de interaccionar con el hueso que rodea al implante, como ocurre cuando el implante es revestido con carbonato cálcico o bien con flúor. Pero sabemos que dentro del metabolismo óseo, juegan importantes papeles, moléculas, como son la melatonina y la hormona del crecimiento entre otras, las cuales deben de ser tenidas en cuenta a la hora de hablar de osteointegración. Se realiza una breve descripción de la fisiología de ambas moléculas y se valora su aplicación al concepto de superficie bioactiva en implantología (AU)
ABSTRACT
At present, after years of investigation in implantology, in which there have been realized a lot of works, with different types of surfaces of implants, smooth and rough, in an attempt of improving, both in the time and in the quality, the osteointegration, one has concluded that the implants of rough surface with an interval of rugosity between 1.0-2.0 nm, are those who seem to give a better bone response and better clinical results, but from an exclusively mechanical point of view. Nowadays the investigations centre on the development of named bioactive surfaces, which are capable to react with the bone around the implant, since it happens when the implant is redressed in carbonate cálcico or in fluorine. But we know that inside the bone metabolism, there are another important molecules the melatonin and the hormone of the growth between others, which must be born in mind at the time of speaking of osteointegration. There is realized a brief description of the physiology of both molecules and his application is valued to the concept of bioactive surface in implantology (AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Aparelhos Ortodônticos Removíveis / Implantação Dentária Limite: Humanos Idioma: Espanhol Revista: Av. periodoncia implantol. oral Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Universidad de Granada/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Aparelhos Ortodônticos Removíveis / Implantação Dentária Limite: Humanos Idioma: Espanhol Revista: Av. periodoncia implantol. oral Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Universidad de Granada/España
...