Your browser doesn't support javascript.
loading
Técnicas fotoelásticas aplicadas al estudio de prótesis sobre implantes / No disponible
Batista, José M. ; Escuin, Tomás.
Afiliação
  • Batista, José M. ; Universitat de Barcelona. Barcelona. España
  • Escuin, Tomás; Universitat de Barcelona. Barcelona. España
Dentum (Barc.) ; 7(1): 24-30, ene.-mar. 2007. ilus
Artigo em Es | IBECS | ID: ibc-056031
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Se estudia, mediante métodos fotoelásticos, si el tipo de implante utilizado para soportar una prótesis es un factor que influye en la obtención de una distribución de cargas que minimice las fuerzas soportadas por el mismo. Se utilizan implantes de tres marcas distintas (Steri-Oss, Endopóre y 31), colocados por pares en tres modelos fotoelásticos de características iguales y se coloca un mismo puente de metal-porcelana en cada uno de ellos. Sobre cada modelo, se aplican fuerzas verticales oclusales en al primer molar y oblicuas oclusales en el canino. Se observan los modelos a través de un haz de luz polarizada para obtener las distribuciones de cargas en los mismos. Los análisis cualitativos de cada uno de los patrones cromáticos generados revelan que, en todos los casos, se obtiene una distribución mínima de cargas para el tipo de implantes Steri-Oss. Cuando las fuerzas aplicadas son de poco valor, los modelos con implantes Endopore tienen un peor comportamiento frente al tipo 3I, pero tienden a equiparar su compqrtamiento cuando las fuerzas aplicadas crecen en magnitud, generando patrones de cargas muy similares. Con las limitaciones inherentes a este estudio, se observa que el tipo de implante utilizado en una misma situación protésica, no influye significativamente en la respuesta a las fuerzas aplicadas (AU)
ABSTRACT
Using photoelastic methods, we study whether or not the kind of implant employed to hold prostheses together is a factor that has an influence on the stress distribution that minimizes the strengths supported by the implant itself. We employ three different brands of implants (Steri-Oss, Endopore and 3D, placed in pairs inside three photoelastic models, all of them with similar characteristics, and we put the same metal ceramic bridge over each one. Each model is subjected to vertical occlusal strengths in the first molar and oblique occlusal strengths in the canine. Models are observed through polarized light to obtain the stress distribution on them. In all cases, qualitative analysis of the chromatic patterns show that the minumum distribution of stress is obtained with Steri-Oss brand implants. When strengths are poor in quality, models with Endopore implants perform worse than models with 3.1 implants, but they tend to perform similarly when strengths are greater in maghitude,creating very similar stress patterns, Despite inherent limitations of this study, we can observe that the kind of implant employed in a prosthetic situation, does not have a meaningful effect on the response to strengths applied (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Procedimentos Cirúrgicos Pré-Protéticos Bucais / Análise do Estresse Dentário Tipo de estudo: Estudo prognóstico / Pesquisa qualitativa Limite: Humanos Idioma: Espanhol Revista: Dentum (Barc.) Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Universitat de Barcelona/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Procedimentos Cirúrgicos Pré-Protéticos Bucais / Análise do Estresse Dentário Tipo de estudo: Estudo prognóstico / Pesquisa qualitativa Limite: Humanos Idioma: Espanhol Revista: Dentum (Barc.) Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Universitat de Barcelona/España
...