El control de la calidad en las compresiones torácicas y su relación con la recuperación de pulso / Feedback on chest compression quality variables and their relationship to rate of return of spontaneous circulation
Emergencias (St. Vicenç dels Horts)
; 25(2): 99-104, abr. 2013. tab
Artigo
em Espanhol
| IBECS
| ID: ibc-113338
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Objetivos:
Varios estudios demuestran el incumplimiento de las recomendaciones internacionales en la ejecución de las compresiones torácicas durante la reanimación cardiopulmonar(RCP). Existen dispositivos de ayuda para la realización de la RCP y SAMUR Protección Civil ha implementado uno de ellos (Q-CPR®). El presente estudio analiza si existe asociación entre uso del dispositivo y la recuperación de pulso (RP), describe la ejecución de las compresiones en relación a los estándares de calidad y verifica si alguno de los parámetros medidos puede relacionarse con la RP.Método:
Estudio prospectivo de cohortes. El periodo de reclutamiento fue de noviembre de 2007 a diciembre de 2010. Se incluyó a todo paciente atendido por una parada cardiorrespiratoria (PCR), y el factor de exposición fue el uso de dispositivo Q-CPR®.Resultados:
Se atendieron 892 PCR 108 con Q-CPR® y 784 sin Q-CPR®. Las dos poblaciones fueron comparables en cuanto a las variables predictoras analizadas. Se encontró (..) (AU)ABSTRACT
Background:
Studies have revealed failure to follow international guidelines for performing chest compressions in cardiopulmonary resuscitation (CPR). Certain feedback devices are available for use. One such device (the Q-CPR) has been used in the Madrid Emergency and Rescue Service (SAMUR).Objectives. To analyze whether there is an association between the rate of return of spontaneous circulation (ROSC) and the use of a feedback device, to describe the performance of compressions in comparison with quality standards, and to determine whether any of the measured variables are related to the rate of ROSC.Methods:
Prospective cohort study. Recruitment period November 2007 to December 2010. Inclusion criteria patients with cardiorespiratory arrest attended by the SAMUR. Exposure factor use of a CPR measurement and feedback device.Results:
SAMUR attended 892 cases of cardiorespiratory arrest the Q-CPR was used in 108 patients and 784 were given (AU)
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Contexto em Saúde:
Agenda de Saúde Sustentável para as Américas
/
ODS3 - Saúde e Bem-Estar
Problema de saúde:
Objetivo 9: Redução de doenças não transmissíveis
/
Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis
Base de dados:
IBECS
Assunto principal:
Pulso Arterial
/
Reanimação Cardiopulmonar
/
Assistência Pré-Hospitalar
/
Parada Cardíaca
Tipo de estudo:
Estudo observacional
/
Estudo prognóstico
/
Fatores de risco
Limite:
Humanos
Idioma:
Espanhol
Revista:
Emergencias (St. Vicenç dels Horts)
Ano de publicação:
2013
Tipo de documento:
Artigo
Instituição/País de afiliação:
Ayuntamiento de Madrid/España