Your browser doesn't support javascript.
loading
Satisfacción materna en el ensayo clínico Eficacia de la postura materna en partos con malposiciónf etal occipito posterior / No disponible
Molina Reyes, Cristina Y; Berral Gutiérrez, M Asunción; Castellano Ibáñez, F Daniel; Huete Morales, M Dolores; Martínez García, Encarnación.
Afiliação
  • Molina Reyes, Cristina Y; Hospital de Baza. Unidad de Partos. s. c. España
  • Berral Gutiérrez, M Asunción; Hospital de Baza. Unidad de Partos. s. c. España
  • Castellano Ibáñez, F Daniel; Hospital de Baza. Unidad de Partos. s. c. España
  • Huete Morales, M Dolores; Universidad de Granada. Departamento de estadística. s. c. España
  • Martínez García, Encarnación; Hospital de Guadix. Unidad de Partos. s. c. España
Metas enferm ; 16(9): 60-67, nov. 2013. tab
Artigo em Espanhol | IBECS | ID: ibc-117926
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

OBJETIVO:

analizar la satisfacción de las madres participantes en un ensayo clínico sobre la eficacia de las posturas manos-rodillas (MR) y decúbito lateral (DL) hacia la espalda fetal para conseguir la rotación del feto. Secundariamente se valoró la influencia en la satisfacción de los cuidados recibidos durante el parto, los factores obstétricos y los resultados materno-fetales. MATERIAL Y

MÉTODO:

ensayo clínico multicéntrico con gestantes con posición fetal occipitoposterior que durante el parto adoptaron la postura manos-rodillas (MR) en un grupo y la postura decúbito lateral (DL) en otro grupo. VARIABLES satisfacción materna (medida con la escala COMFORTS adaptada), paridad, rotación fetal a occipitoanterior, analgesia epidural, tipo de parto y test de Apgar. Se llevó a cabo un análisis de regresión logística multivarible.

RESULTADOS:

treinta y ocho mujeres del grupo MR y cuarenta y siete del grupo DL participaron. La lesión abdominal o perineal obtuvo la puntuación de satisfacción más baja (media 4,31 sobre 5; 49,4% de mujeres muy satisfechas); el fomento del vínculo afectivo madre-hijo obtuvo la puntuación más elevada (media 4,92 sobre 5; 91,8% de mujeres muy satisfechas). La vivencia satisfactoria del parto fue superior en el grupo MR (92,1% vs. 87,2%), con Odds Ratio (OR) ajustada a las variables obstétricas de 5,18 (intervalo de confianza (IC) al 95% 1,08-24,82); mayor satisfacción con test de Apgar al minuto> 8 frente a ≤ 8 (90,4% vs. 83,3%), (OR= 5,26; IC95%1,68-16,51).

CONCLUSIONES:

la satisfacción materna fue muy elevada, pero la vivencia satisfactoria del parto fue superior para las mujeres que adoptaron la postura MR. Esta vivencia está influida por los cuidados aportados por la matrona y los resultados obstétricos, especialmente por el estado de salud del bebé
ABSTRACT

OBJECTIVE:

to analyze the satisfaction of mothers participating in a clinical trial about the efficacy of the hands-knees (HK) and lateral decubitus (LD) postures towards the fetal back in order to achieve the rotation of the fetus. Secondarily, the influence of satisfaction regarding care received during labor was also assessed, as well as obstetric factors and mother-fetus outcomes. MATERIALS AND

METHODS:

multicenter clinical trial with pregnant ­women with fetal occiput posterior position, which adopted the hands-knees (HK) posture in one group, and the lateral decubitus (LD) posture in the other group. VARIABLES maternal satisfaction (measured with the adapted COMFORTS scale), parity, fetal rotation to occiput anterior, epidural analgesia, type of labor and Apgar Test. A multivariate logistic regression analysis was conducted.

RESULTS:

thirty-eight women in the HK group and forty-seven in the DL took part in the study. Abdominal or perineal lesion obtained the lowest satisfaction score (mean 4.31 over 5; 49.4% of very satisfied women); the encouragement of mother-child bonding obtained the highest score (mean 4.92 of 5; 91.8% of very satisfied women). The satisfactory experience of labor was higher in the HK group (92.1% vs. 87.2%), with Odds Ratio (OR) adjusted to obstetric variables of 5.18 (Confidence Interval (IC) at 95% 1.08-24.82); higher satisfaction with Apgar Test at 1 minute >8 vs. ≤ 8 (90.4% vs. 83.3%), (OR= 5.26; IC95%1.68-16.51).

CONCLUSIONS:

maternal satisfaction was very high, but the satisfactory labor experience was higher in those women who adopted the HK position. This experience is influenced by the care provided by the midwife and the obstetric results, particularly by the health status of the baby
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Parto Obstétrico / Posicionamento do Paciente / Apresentação no Trabalho de Parto Tipo de estudo: Ensaio clínico controlado Aspecto: Preferência do paciente Limite: Feminino / Humanos / Gravidez Idioma: Espanhol Revista: Metas enferm Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Hospital de Baza/España / Hospital de Guadix/España / Universidad de Granada/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Parto Obstétrico / Posicionamento do Paciente / Apresentação no Trabalho de Parto Tipo de estudo: Ensaio clínico controlado Aspecto: Preferência do paciente Limite: Feminino / Humanos / Gravidez Idioma: Espanhol Revista: Metas enferm Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Hospital de Baza/España / Hospital de Guadix/España / Universidad de Granada/España
...