Your browser doesn't support javascript.
loading
Fiabilidad interobservador de la escala del coma de Glasgow en pacientes críticos con enfermedad neurológica o neuroquirúrgica / Interobserver reliability of the Glasgow coma scale in critically ill patients with neurological and/or neurosurgical disease
Sánchez-Sánchez, MM; Sánchez-Izquierdo, R; Sánchez-Muñoz, EI; Martínez-Yegles, I; Fraile-Gamo, MP; Arias-Rivera, S.
Afiliação
  • Sánchez-Sánchez, MM; Hospital Universitario de Getafe. Servicio de Cuidados Intensivos. Madrid. España
  • Sánchez-Izquierdo, R; Hospital Universitario de Getafe. Servicio de Cuidados Intensivos. Madrid. España
  • Sánchez-Muñoz, EI; Hospital Universitario de Getafe. Servicio de Cuidados Intensivos. Madrid. España
  • Martínez-Yegles, I; Hospital Universitario de Getafe. Servicio de Cuidados Intensivos. Madrid. España
  • Fraile-Gamo, MP; Hospital Universitario de Getafe. Servicio de Cuidados Intensivos. Madrid. España
  • Arias-Rivera, S; Hospital Universitario de Getafe. Servicio de Cuidados Intensivos. Madrid. España
Enferm. intensiva (Ed. impr.) ; 25(1): 15-23, ene.-mar. 2014. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-120984
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

INTRODUCCIÓN:

La escala del coma de Glasgow (GCS) es un instrumento simple y habitual en la evaluación neurológica del paciente crítico. A pesar de su extendido uso, la GCS tiene algunas limitaciones pues, ocasionalmente, distintos observadores pueden valorar de forma diferente una misma respuesta.

OBJETIVO:

Evaluar la concordancia interobservador, entre enfermeras de intensivos con un mínimo de 3 años de experiencia, en la estimación global de la GCS y de cada uno de sus componentes.

MÉTODO:

Estudio observacional prospectivo, incluyendo a 110 pacientes neurológicos o neuroquirúrgicos, realizado en una unidad polivalente de 18 camas, desde octubre de 2010 hasta diciembre de 2012. Variables registradas demográficas, motivo de ingreso, puntuación GCS global y de sus componentes. La valoración neurológica fue realizada por un mínimo de 3 enfermeras. Una aplicaba el algoritmo y la técnica de evaluación consensuada y todas, independientemente, valoraban la respuesta a los estímulos. Se mide la concordancia interobservador mediante el coeficiente de correlación intraclase (CCI) con intervalo de confianza (IC) del 95%. Este estudio fue aprobado por el Comité Ético de Ensayos Clínicos del hospital.

RESULTADOS:

El CCI (IC 95%) para la escala fue GCS global 0,989 (0,985-0,992); respuesta ocular 0,981 (0,974-0,986); respuesta verbal 0,971 (0,960-0,979); respuesta motora 0,987 (0,982-0,991).

CONCLUSIÓN:

En nuestra cohorte de pacientes hemos observado un alto nivel de concordancia tanto en la aplicación de la GCS como en cada uno de sus componentes
ABSTRACT

INTRODUCTION:

The Glasgow coma scale (GCS) is a common tool used for neurological assessment of critically ill patients. Despite its widespread use, the GCS has some limitations, as sometimes different observers may value differently the same response.

OBJECTIVE:

To evaluate the interobserver agreement, among intensive care nurses with a minimum of 3 years experience, both in the overall estimate of GCS and for each of its components.

METHODS:

Prospective observational study including 110 neurological and/or neurosurgical patients conducted in a critical care unit of 18 beds, from October 2010 until December 2012. Registered variables Demographic characteristics, reason for admission, overall GCS and its components. The neurological evaluation was conducted by a minimum of 3 nurses. One of them applied an algorithm and consensual assessment technique and all, independently, valued response to stimuli. Interobserver agreement was measured using the intraclass correlation coefficient (ICC) for a confidence interval (CI) of 95%. The study was approved by the Ethics Committee for Clinical Trails.

RESULTS:

The intraclass correlation coefficient (confident interval) for scale was Overall GCS0.989 (0.985-0.992); ocular response 0.981 (0.974-0.986); verbal response 0.971 (0.9600.979); motor response 0.987 (0.982-0.991).

CONCLUSION:

In our cohort of patients we observed a high level of consistency in the application of both the GCS as in each of its components
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doenças do Sistema Nervoso Central / Estado Terminal Tipo de estudo: Estudo observacional Aspecto: Aspectos éticos Limite: Humanos Idioma: Espanhol Revista: Enferm. intensiva (Ed. impr.) Ano de publicação: 2014 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario de Getafe/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doenças do Sistema Nervoso Central / Estado Terminal Tipo de estudo: Estudo observacional Aspecto: Aspectos éticos Limite: Humanos Idioma: Espanhol Revista: Enferm. intensiva (Ed. impr.) Ano de publicação: 2014 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario de Getafe/España
...