Your browser doesn't support javascript.
loading
Resultados visuales, independencia de gafas e insatisfacción tras implante de una lente intraocular difractiva trifocal / Visual outcomes, spectacle independence and satisfaction after diffractive trifocal intraocular lens implantation
Llovet-Rausell, A; Llovet-Osuna, F; Bilbao-Calabuig, R; Martínez del Pozo, M; Ortega-Usobiaga, J; Baviera-Sabater, J.
Afiliação
  • Llovet-Rausell, A; Universidad Autónoma de Barcelona. Instituto Universitario Barraquer. Barcelona. España
  • Llovet-Osuna, F; Clínica Baviera. Departamento de cirugía refractiva y catarata. Madrid. España
  • Bilbao-Calabuig, R; Clínica Baviera. Departamento de cirugía refractiva y catarata. Madrid. España
  • Martínez del Pozo, M; Clínica Baviera. Departamento de cirugía refractiva y catarata. Madrid. España
  • Ortega-Usobiaga, J; Clínica Baviera. Departamento de cirugía refractiva y catarata. Bilbao. España
  • Baviera-Sabater, J; Clínica Baviera. Departamento de cirugía refractiva y catarata. Valencia. España
Arch. Soc. Esp. Oftalmol ; 93(10): 481-490, oct. 2018. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-175122
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

OBJETIVO:

Evaluar los resultados visuales, la independencia de gafas y la satisfacción tras el implante de una lente intraocular trifocal.

MÉTODOS:

Estudio retrospectivo de 5.186 sujetos intervenidos de facoemulsificación con implante de la lente trifocal difractiva FineVision Micro F12 (PhysIOL, Liège, Bélgica).

RESULTADOS:

La queratometría media preoperatoria fue 43,61±1,55 D y el cilindro queratométrico medio -0,86 ± 0,66 D. A los 3 meses, cambiaron a 43,59±1,56 y −0,71±0,46 D respectivamente. La esfera media pasó de 2,04±2,60 a 0,14±0,38 D y el equivalente esférico medio de 1,64±2,61 a −0,05±0,36 D. Más del 60% alcanzaron una mejor agudeza visual corregida de lejos. La mayoría presentó un defecto residual final (predictibilidad) menor de 1 D (99,1%). El 14,3% precisó un ajuste refractivo, el 2,2% capsulotomía posterior y se recolocó la lente intraocular en 5 casos. Un porcentaje elevado estaba satisfecho en términos de visión e independencia de gafas en todas las distancias. Aunque un 2% refirió un empeoramiento en la visión nocturna, únicamente un 2% estaba poco satisfecho y 20 pacientes insatisfechos. Las causas fueron visión borrosa (7 casos), necesidad de gafas (10), disfotopsias (7) y sequedad ocular (4).

CONCLUSIONES:

La implantación de esta lente permite obtener buenos resultados visuales en las 3 distancias así como un alto grado de independencia de gafas y de satisfacción
ABSTRACT

PURPOSE:

To investigate visual outcomes, spectacle independence, and patient satisfaction after trifocal intraocular lens implantation.

METHODS:

A retrospective study conducted on 5,186 patients who underwent phacoemulsification and were implanted with a diffractive trifocal intraocular lens (FineVision Micro F, PhysIOL SA, Liège, Belgium).

RESULTS:

The mean pre-operative keratometry was 43.61±1.55 D, and mean keratometric cylinder was -0.86±0.66 D. At 3 months post-operatively, values changed to 43.59±1.56 and -0.71±0.46 D, respectively. Mean sphere varied from 2.04±2.60 to 0.14±0.38 D, and mean spherical equivalent from 1.64±2.61 to -0.05±0.36 D. More than 60% of the patients achieved better corrected distance visual acuity. The majority had a final residual refractive error (predictability) lower than 1 D (99.1%), with 14.3% needing optical adjustment (bioptics). Posterior capsulotomy was performed in 2.2%, and the lens was replaced in 5 patients. A high percentage of patients were satisfied in terms of vision and spectacle independence at all distances. Although 2% referred to worsening of night vision quality, only 2% were not very satisfied and 20 patients were dissatisfied. The causes were blurred vision (7 cases), spectacle dependence (10), dysphotopsia (7), and dry eye (4).

CONCLUSIONS:

The implantation of this model provided good visual performance in all distances, as well as high levels of spectacle independence and satisfaction
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Satisfação do Paciente / Facoemulsificação / Óculos / Lentes Intraoculares Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Clínica Baviera/España / Universidad Autónoma de Barcelona/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Satisfação do Paciente / Facoemulsificação / Óculos / Lentes Intraoculares Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Clínica Baviera/España / Universidad Autónoma de Barcelona/España
...