Your browser doesn't support javascript.
loading
Uso de un nuevo dispositivo para la prevención de embolias pulmonares previo a una trombectomía farmacomecánica / Using a new device to prevent pulmonary embolisms during pharmacomechanical thrombectomy
Calleja, E; Ciampi, JJ; Puche, JJ; Lanciego, C.
Afiliação
  • Calleja, E; Complejo Hospitalario de Toledo. Hospital Virgen de la Salud. Unidad de Radiología Intervencionista. Toledo. España
  • Ciampi, JJ; Complejo Hospitalario de Toledo. Hospital Virgen de la Salud. Unidad de Radiología Intervencionista. Toledo. España
  • Puche, JJ; Complejo Hospitalario de Toledo. Hospital Virgen de la Salud. Unidad de Corta Estancia de Medicina Interna. Toledo. España
  • Lanciego, C; Complejo Hospitalario de Toledo. Hospital Virgen de la Salud. Unidad de Radiología Intervencionista. Toledo. España
Radiología (Madr., Ed. impr.) ; 60(6): 517-520, nov.-dic. 2018. ilus
Artigo em Espanhol | IBECS | ID: ibc-175331
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Hemos empleado un nuevo dispositivo para prevenir la tromboembolia pulmonar (TEP) durante una trombectomía farmacomecánica en una mujer puérpera de 25 años. El catéter Angel(R) (BiO2 Medical Inc. Golden, CO) es un dispositivo temporal que combina la función de filtro de vena cava (FVC) con la de un catéter venoso central de triple luz. Normalmente, la prevención de la TEP durante la trombectomía farmacomecánica se realiza implantando un FVC. Las complicaciones asociadas al FVC aumentan con el tiempo de implantación. Su recuperabilidad no es total y la iatrogenia es posible tanto al implantarlo como al retirarlo. En nuestra experiencia, este nuevo dispositivo puede ser implantado y extraído de forma mucho más sencilla. Creemos interesante dar a conocer este dispositivo como una posible alternativa al FVC para prevenir la TEP durante la trombectomía farmacomecánica, como exponemos en este caso
ABSTRACT
We have used a new device to prevent pulmonary embolism during pharmacomechanical thrombectomy in a 25-year-old postpartum woman. The Angel(R) catheter (BiO2 Medical Inc., Golden, CO, USA) is a temporary device that combines the functions of a vena cava filter (VCF) with those of a triple-lumen central venous catheter. Normally, a VCF is implanted to prevent pulmonary embolism during pharmacomechanical thrombectomy. However, the complications associated with VCFs increase with time, not all of the filter can always be retrieved, and there can be iatrogenic effects both during implantation and retrieval. In our experience, this new device is much simpler to deploy and to retrieve. As is shown in this case, this temporary device can be an interesting alternative to a VCF for preventing pulmonary embolisms during pharmacomechanical thrombectomy
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: Agenda de Saúde Sustentável para as Américas / ODS3 - Saúde e Bem-Estar Problema de saúde: Objetivo 9: Redução de doenças não transmissíveis / Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis Base de dados: IBECS Assunto principal: Embolia Pulmonar / Filtros de Veia Cava / Trombectomia / Trombose Venosa Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario de Toledo/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: Agenda de Saúde Sustentável para as Américas / ODS3 - Saúde e Bem-Estar Problema de saúde: Objetivo 9: Redução de doenças não transmissíveis / Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis Base de dados: IBECS Assunto principal: Embolia Pulmonar / Filtros de Veia Cava / Trombectomia / Trombose Venosa Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario de Toledo/España
...