Your browser doesn't support javascript.
loading
El polietileno de alto entrecruzamiento no reduce el desgaste en la artroplastia total de rodilla / Cross-linked polyethylene does not reduce wear in total knee arthroplasty
Lasurt-Bachs, S; Torner, P; Maculé, F; Prats, E; Menéndez-García, F; Ríos-Guillermo, J; Torrents, A.
Afiliação
  • Lasurt-Bachs, S; Consorci Sanitari Integral Baix Llobregat. Servei de Cirurgia Ortopèdica i Traumatologia. Unitat de Genoll. Barcelona. España
  • Torner, P; Parc Taulí Hospital Universitari. Servei de Cirurgia Ortopèdica i Traumatologia. Sabadell. España
  • Maculé, F; Hospital Clínic. Servicio de Cirugía Ortopédica y Traumatología. Unidad de Rodilla. Barcelona. España
  • Prats, E; Centres Científics i Tecnològics de la Universitat de Barcelona (CCiTUB). Departamento de Microscopía Electrónica. Barcelona. España
  • Menéndez-García, F; Centres Científics i Tecnològics de la Universitat de Barcelona (CCiTUB). Unidad de Análisis Elemental. Barcelona. España
  • Ríos-Guillermo, J; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS). Departamento de Estadística. Barcelona. España
  • Torrents, A; Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS). Departamento de Estadística. Barcelona. España
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 62(3): 197-203, mayo-jun. 2018. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-177323
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Comparar dos pares de fricción (metal/polietileno de ultra alto peso molecular [UHMWPE], metal/polietileno de alto entrecruzamiento) mediante análisis cuantitativo y cualitativo de partículas de polietileno en líquido sinovial a los 3 años postintervención en pacientes portadores de prótesis total de rodilla (PTR). Material y

métodos:

Se llevó a cabo un estudio de cohortes prospectivo, aleatorizado, con evaluación ciega incluyendo 25 pacientes a quienes se intervino de PTR de manera bilateral, con 6 meses de diferencia. A los 3 años postintervención, se realizaron artrocentesis de rodilla a 12 pacientes y se analizaron las partículas de polietileno.

Resultados:

No se hallaron diferencias significativas en el número de partículas generadas por los diferentes insertos de polietileno a los 3 años tras la implantación de una artroplastia total de rodilla (3.000× x¯ entrecruzado=849,7; x¯ UHMWPE=796,9; p=0,63; 20.000× x¯ entrecruzado=66,3; x¯ UHMWPE=73,1; p=0,76). Tampoco existen diferencias significativas entre los 2 tipos de inserto, entre la posibilidad de encontrar partículas de forma elongada (χ2=0,19; p=0,66) ni redonda (χ2=1,44; p=0,23). Sin embargo, la probabilidad de encontrar partículas de forma fibrilar es 3,08 veces mayor en el UHMWPE.

Conclusiones:

El polietileno altamente entrecruzado no reduce significativamente la generación de partículas de polietileno en aquellos pacientes intervenidos mediante una artroplastia total de rodilla, con muestras a 3 años postintervención
ABSTRACT

Aim:

To compare two different types of inserts Ultra-high molecular weight polyethylene (UHMWPE) and cross-linked polyethylene with a quantitative and qualitative study of polyethylene wear particles in synovial fluid 3 years after total knee arthroplasty. Material and

methods:

A prospective, randomized, controlled cohort study with blinded evaluation was carried out on 25 patients undergoing staged bilateral total knee replacement, 6 months apart. Knee arthrocentesis was performed on 12 patients 3 years after surgery, and the polyethylene particles were analyzed.

Results:

No significant differences were found in the number of particles generated by the two different types of inserts at 3 years from total knee arthroplasty (3,000× x¯ cross-linked=849.7; x¯ UHMWPE=796.9; P=.63; 20,000× x¯ cross-linked=66.3; x¯ UHMWPE=73.1; P=.76). Likewise, no differences in the probability of finding elongated (χ2=0.19; P=.66) or rounded (χ2=1.44; P=.23) particles in both types of inserts were observed. However, the probability of finding fibrillar particles is 3.08 times greater in UHMWPE.

Conclusions:

Cross-linked polyethylene does not significantly reduce the generation of polyethylene particles in patients with total knee arthroplasty, 3 years after the surgical procedure
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Prótese do Joelho Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Centres Científics i Tecnològics de la Universitat de Barcelona (CCiTUB)/España / Consorci Sanitari Integral Baix Llobregat/España / Hospital Clínic/España / Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS)/España / Parc Taulí Hospital Universitari/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Artroplastia do Joelho / Osteoartrite do Joelho / Prótese do Joelho Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Centres Científics i Tecnològics de la Universitat de Barcelona (CCiTUB)/España / Consorci Sanitari Integral Baix Llobregat/España / Hospital Clínic/España / Institut d'Investigacions Biomèdiques August Pi i Sunyer (IDIBAPS)/España / Parc Taulí Hospital Universitari/España
...