Estudio descriptivo de monitorización de un programa de calidad de sedación por no anestesiólogos / A descriptive monitoring study of a non-anesthetist sedation quality program
Rev. esp. enferm. dig
; 111(1): 55-62, ene. 2019. tab, graf
Artigo
em Espanhol
| IBECS
| ID: ibc-182160
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción:
la sedación mejora sensiblemente la calidad de la endoscopia digestiva, aunque puede tener complicaciones graves.Métodos:
protocolo multidisciplinar en base a la joint comission que defina el protocolo de sedación por no anestesiólogos. Se excluyen pacientes ASA 4 o con vía aérea difícil, pruebas complejas y sedación profunda. Controlamos la calidad en base al análisis de 9 indicadores. También se monitorizan las pruebas incompletas para valorar eficacia.Resultados:
la seguridad del paciente se establece en base a una incidencia de complicaciones muy baja, con una incidencia de eventos respiratorios de 1,07. Además, se encuentra una baja incidencia de hipotensión y bradicardia, al igual que del dolor durante y después de la endoscopia y una incidencia menor del 0,5% de ingresos no esperados. Los indicadores de calidad medidos nos indican la evolución de los resultados del programa.Conclusiones:
la monitorización continuada de los programas de sedación en endoscopia permiten controlar las diferentes dimensiones de la calidad e implementar medidas que mejoren el procesoABSTRACT
Introduction:
sedation substantially improves the quality of digestive endoscopy procedures but may result in severe complications.Methods:
a joint commission-based multidisciplinary protocol was used to define a protocol for sedation by non-anesthesiologists. ASA 4 patients were excluded, as well as patients with a difficult airway, complex procedures and deep sedation. Quality based on the analysis of 9 indicators were monitored. Incomplete procedures were also monitored in order to assess efficacy.Results:
patient safety was established based on a very low incidence of complications and a rate of respiratory events of 1.07. Furthermore, a low rate of hypotension and bradycardia was found, as well as a low rate of pain, either during or after endoscopy and an incidence of unexpected admissions lower than 0.5%. The quality indicators measured reflect the evolution of the results of the program.Conclusions:
ongoing sedation program monitoring in endoscopy allows the control of different quality dimensions and the implementation of steps for process improvement
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Sedação Consciente
/
Endoscopia do Sistema Digestório
/
Monitoramento de Medicamentos
/
Anestésicos
Limite:
Adulto
/
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Rev. esp. enferm. dig
Ano de publicação:
2019
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital Clínico Universitario de Santiago/España
/
Hospital Povisa/España