Stent micromallado para el tratamiento del aneurisma cervical sintomático de la arteria carótida interna / Micromesh stent for treating a of symptomatic cervical internal carotid artery aneurysm
Angiol. (Barcelona)
; 74(1): 34-37, ene.-feb.,2022. ilus
Artigo
em Espanhol
| IBECS
| ID: ibc-202755
Biblioteca responsável:
ES1.1
Localização: ES15.1 - BNCS
RESUMEN
Introducción:
el manejo y tratamiento de un aneurisma carotídeo espontáneo mediante técnica endovascularmínimamente invasiva es un procedimiento poco frecuente y que en este caso resultó en la exclusión de la circulación del aneurisma manteniendo la permeabilidad de la arteria carótida interna y sus ramas terminales cerebrales.Caso clínico presentamos el caso de un hombre de 61 años con antecedente de hipertensión arterial y seis eventoscerebrovasculares previos con microlesiones cerebrales sin focalidad neurológica. La investigación angiográfi careveló un aneurisma de arteria carótida interna izquierda segmento cervical (C1) de cuello ancho, sacular, causanteposiblemente de la sintomatología del paciente.Discusión:
se indicó manejo percutáneo endovascular defi nitivo del aneurisma utilizado técnica estándar y colocación de stent micromallado (CGuard), cubriendo el cuello y logrando la exclusión inmediata del aneurismacarotídeo. El seguimiento al mes del procedimiento confi rmó el cierre, la permeabilidad carotídea y resolución desintomatología.ABSTRACT
Introduction:
the management and treatment of a spontaneous carotid aneurysm using a minimally invasiveendovascular technique is a rare procedure. This case resulted in the exclusion of the aneurysm from circulation,maintaining the patency of the internal carotid artery and its terminal cerebral branches.Case report we present the case of a 61-year-old man with a history of arterial hypertension and six previouscerebrovascular events with brain micro-injuries without neurological focus. Angiographic investigation revealedan aneurysm of the left internal carotid artery, cervical segment (C1) of wide neck, saccular, possibly causing thepatients symptoms.Discussion:
defi nitive percutaneous endovascular management of the aneurysm was indicated using standardtechnique and micro malted stent placement (CGuard), covering the neck and achieving immediate exclusion ofthe carotid aneurysm. Follow-up one month after the procedure confi rmed closure, carotid patency and resolutionof symptoms.
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Stents
/
Ciências da Saúde
/
Aneurisma
Limite:
Adulto
Idioma:
Espanhol
Revista:
Angiol. (Barcelona)
Ano de publicação:
2022
Tipo de documento:
Artigo
Instituição/País de afiliação:
Axxis Hospital/Ecuador
/
Axxis Hospital. Servicio de Angiografía/Ecuador