Material y sedoanalgesia en el procedimiento de punción lumbar neonatal / Material and sedation-analgesia in the neonatal lumbar puncture procedure
An. pediatr. (2003. Ed. impr.)
; 95(4): 246-252, Oct. 2021. ilus, tab
Artigo
em Espanhol
| IBECS
| ID: ibc-207786
Biblioteca responsável:
ES1.1
Localização: ES15.1 - BNCS
RESUMEN
Introducción:
La punción lumbar (PL) es un procedimiento que se realiza con frecuencia durante el período neonatal. Efectuar correctamente esta técnica puede evitar gran parte de sus complicaciones.Objetivo:
Evaluar el procedimiento de PL en neonatos en los hospitales españoles, estudiando el tipo de material empleado y la sedoanalgesia utilizada. Material ymétodos:
Estudio transversal basado en una encuesta escrita distribuida por correo electrónico a través de la Red de Hospitales Segurneo-SEN y la Sociedad Española de Neonatología, que recogía datos sobre la técnica de PL en neonatos.Resultados:
Se analizaron 301 encuestas respondidas. La mayoría de profesionales utilizaban aguja tipo trocar con estilete como primera opción (89,7%). No obstante, cuando la PL era fallida o hemática el 32,2% cambiaba el tipo de aguja. Del total de médicos, 143 reflejaron su sensación subjetiva sobre el tipo de aguja el 41,3% solo empleaban agujas tipo trocar, al 32,2% la técnica les resultaba más fácil empleando agujas de tipo «palomilla», para el 7,7% existía menor probabilidad de PL hemática o fallida usando agujas de tipo «palomilla», el 10,5% elegían aguja dependiendo del tamaño del neonato, y un 8,4% eran indiferentes a utilizar un tipo u otro de aguja. El 99% de los encuestados usaban algún tipo de analgesia. Las medidas más utilizadas fueron anestésicos tópicos (90,3%) y sacarosa (82,2%).Conclusiones:
Actualmente, el procedimiento de PL en neonatos se realiza de forma mayoritaria utilizando agujas tipo trocar con estilete y con un uso extendido de diferentes medidas analgésicas para llevar a cabo la técnica. (AU)ABSTRACT
Introduction:
Lumbar puncture (LP) is a frequent procedure during the neonatal period. Correctly performing this technique can avoid many of its complications.Objective:
To evaluate the LP procedure in neonates in Spanish hospitals, studying the type of material and the sedation-analgesia used. Material andmethods:
Cross-sectional study conducted in Spain gathering data through a survey research distributed by email through the Segurneo-SEN Hospital Network and the Spanish Neonatal Society. Data on the LP technique in neonates were collected.Results:
A total of 301 participants were analysed. Most professionals used a trocar needle with a stylet as the first option (89.7%); however, when the LP failed or was blood-stained, 32.2% changed the type of needle. A total of 143 doctors gave their subjective feeling about the type of needle they only use trocar needles with stylet (41.3%), the technique is easier using scalp-vein needles (32.2%), there is less probability of a blood-stained LP, or failed using scalp-vein needles (7.7%), they choose the type of needle depending on the size of the new-born (10.5%), indifference when using one type or another needle (8.4%). Almost all (99%) of the surveyed doctors used some type of analgesia. The most widely used measures were topical anaesthetics (90.3%) and sucrose (82.2%).Conclusions:
Currently, the LP procedure in the neonatal period is mainly performed with a trocar needle with a stylet and with the widespread use of different analgesic measures. (AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Punção Espinal
/
Analgesia
Limite:
Humanos
/
Recém-Nascido
País/Região como assunto:
Europa
Idioma:
Espanhol
Revista:
An. pediatr. (2003. Ed. impr.)
Ano de publicação:
2021
Tipo de documento:
Artigo
Instituição/País de afiliação:
HM Hospitales/España
/
Universidad San Pablo CEU/España