Your browser doesn't support javascript.
loading
Efecto de los segmentos anulares intracorneales en la topografía corneal posterior en ojos con queratocono / Effect of intracorneal ring segments on posterior corneal topography in eyes with keratoconus
Berty, M. M; Eliwa, T. F; Gaafar, A. A. M; Mousa, A. S.
Afiliação
  • Berty, M. M; Ain Shams University. Faculty of Medicine. Assistant Lecturer of Ophthalmology and Ophthalmic Surgery. Cairo. Egipto
  • Eliwa, T. F; Ain Shams University. Faculty of Medicine. Assistant Professor of Ophthalmology and Ophthalmic Surgery. Cairo. Egipto
  • Gaafar, A. A. M; Ain Shams University. Faculty of Medicine. Professor of Ophthalmology and Ophthalmic Surgery. Cairo. Egipto
  • Mousa, A. S; Ain Shams University. Faculty of Medicine. Professor of Ophthalmology and Ophthalmic Surgery. Cairo. Egipto
Arch. Soc. Esp. Oftalmol ; 97(8): 424-431, ago. 2022. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-209092
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN
Objetivo Analizar los cambios en las superficies corneales anterior y posterior medidos con un dispositivo de imágenes Scheimpflug en pacientes con queratocono implantados con segmentos anulares intracorneales y correlacionar esos cambios con los resultados visuales. Métodos Este estudio prospectivo de serie de casos de intervención incluyó 92 ojos de 60 pacientes con queratocono a los que se implantó segmentos anulares intracorneales de Kerarings (Mediphacos, Belo Horizonte, Brasil). Se evaluaron las lecturas queratométricas (K), la asfericidad corneal (valor Q) y las elevaciones de las superficies corneales anterior y posterior mediante un dispositivo de imágenes Scheimpflug antes de la operación y a los uno, 3, 6 y 12 meses después de la misma. Resultados La mejor agudeza visual corregida (MAVC) mejoró de 0,61 a 0,19 logMAR a los 12 meses de la cirugía. Tanto la superficie corneal anterior como la posterior mostraron un aplanamiento significativo con una reducción estadísticamente significativa de la lectura K anterior media en 3,39 D y de la lectura K posterior media en 0,39 D (p<0,001) a los 12 meses. Se observó un cambio estadísticamente significativo del Q anterior a un valor menos negativo (de −1,05 a −0,36) (p<0,001) sin que se produjera ningún cambio significativo en el valor del Q posterior. La mejora del Q anterior se correlacionó significativamente con una mejor MAVC postoperatoria (p=0,03). Una mejor MAVC postoperatoria se correlacionó significativamente con una mejor MAVC preoperatoria, una K anterior y posterior más plana, un valor Q anterior menos prolato y menores elevaciones anteriores. Conclusiones La implantación de segmentos anulares intracorneales tiene un efecto de aplanamiento significativo en las superficies corneales anteriores y posteriores. La mejora de la asfericidad corneal se correlaciona con un mejor resultado visual. Algunos parámetros preoperatorios fueron factores predictivos de la mejora visual postoperatoria (AU)
ABSTRACT
Purpose To analyze the changes in the anterior and posterior corneal surfaces measured with a Scheimpflug imaging device in keratoconus patients implanted with intracorneal ring segments and to correlate those changes with the visual outcomes. Methods This prospective interventional case series study included 92 eyes of 60 patients with keratoconus who underwent Kerarings (Mediphacos, Belo Horizonte, Brazil) intracorneal ring segments implantation. Keratometric (K) readings, corneal asphericity (Q value) and elevations of both anterior and posterior corneal surfaces were evaluated using a Scheimpflug imaging device preoperatively and at one, 3, 6 and 12 months after surgery. Result The mean best corrected visual acuity (BCVA) improved from 0.61 to 0.19 logMAR at 12 months after surgery. Both anterior and posterior corneal surfaces showed significant flattening with statistically significant reduction of the mean anterior K reading by 3.39 D and the mean posterior K reading by 0.39 D (P<.001) at 12 months. Statistically significant change of the anterior Q to a less negative value (from −1.05 to −0.36) was observed (P<.001) with no significant change of the posterior Q value. Improvement of the anterior Q was significantly correlated to better postoperative BCVA (P=.03). Better postoperative BCVA significantly correlated to better preoperative BCVA, flatter preoperative anterior and posterior K, less prolate anterior Q value and lower anterior elevations. Conclusions Implanted with intracorneal ring segments implantation has a significant flattening effect on both anterior and posterior corneal surfaces. Improvement of corneal asphericity is correlated to better visual outcome. Certain preoperative parameters were predictive factors of the postoperative visual improvement (AU)
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Substância Própria / Ceratocone Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Ain Shams University/Egipto
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Substância Própria / Ceratocone Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Ain Shams University/Egipto
...