Your browser doesn't support javascript.
loading
Utilidad de la ecografía de nervio óptico como predictor de progresión en esclerosis múltiple / Usefulness of optic nerve ultrasound to predict clinical progression in multiple sclerosis
Pérez Sánchez, S; Eichau Madueño, S; Rus Hidalgo, M; Domínguez Mayoral, A. M.; Vilches-Arenas, A; Navarro Mascarell, G; Izquierdo, G.
Afiliação
  • Pérez Sánchez, S; Hospital Universitario Virgen Macarena. Sevilla. España
  • Eichau Madueño, S; Hospital Universitario Virgen Macarena. Sevilla. España
  • Rus Hidalgo, M; Hospital Universitario Virgen Macarena. Sevilla. España
  • Domínguez Mayoral, A. M.; Hospital Universitario Virgen Macarena. Sevilla. España
  • Vilches-Arenas, A; Hospital Universitario Virgen Macarena. Sevilla. España
  • Navarro Mascarell, G; Hospital Universitario Virgen Macarena. Sevilla. España
  • Izquierdo, G; Hospital Universitario Virgen Macarena. Sevilla. España
Neurología (Barc., Ed. impr.) ; 36(3): 209-214, abril 2021. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-219732
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN

Introducción:

La pérdida neuronal/axonal progresiva se considera la causa más importante de discapacidad neurológica en la esclerosis múltiple (EM). El sistema visual está frecuentemente afectado en esta enfermedad y su accesibilidad a test funcionales y estructurales ha permitido que se convierta en un modelo para estudiar in vivo la patogenia de la EM. La ecografía orbitaria permite evaluar, de forma no invasiva y en tiempo real, las diversas estructuras de la órbita, incluido el nervio óptico.Material y métodosSe ha llevado a cabo un estudio observacional ambispectivo en pacientes con EM recogiéndose datos evolutivos de la enfermedad. La ecografía orbitaria se realizó en todos los pacientes según el principio de mínima potencia necesaria (ALARA). También se recogieron los datos de tomografía de coherencia óptica (OCT) en aquellos que tenían realizadas ambas pruebas. El estudio estadístico se efectuó con el programa SPSS 22.0.ResultadosSe encontraron correlaciones estadísticamente significativas entre las medidas ecográficas y la progresión de la enfermedad (p = 0,041 para el ojo derecho y p = 0,037 para el ojo izquierdo), y la Expanded Disability Status Scale (EDSS) final en el seguimiento (p = 0,07 para el ojo derecho y p = 0,043 para el ojo izquierdo). No fue así para los datos referentes a brotes y a otras variables clínicas.DiscusiónLa medición del diámetro del nervio óptico por ecografía podría utilizarse como medida predictiva en la evolución de la EM, ya que la disminución del mismo se asocia con progresión clínica y mayor discapacidad, medidas con la EDSS. (AU)
ABSTRACT

Introduction:

Progressive neuronal and axonal loss are considered the main causes of disability in patients with multiple sclerosis (MS). The disease frequently involves the visual system; the accessibility of the system for several functional and structural tests has made it a model for the in vivo study of MS pathogenesis. Orbital ultrasound is a non-invasive technique that enables various structures of the orbit, including the optic nerve, to be evaluated in real time.Material and methodsWe conducted an observational, ambispective study of MS patients. Disease progression data were collected. Orbital ultrasound was performed on all patients, with power set according to the ‘as low as reasonably achievable’ (ALARA) principle. Optical coherence tomography (OCT) data were also collected for those patients who underwent the procedure. Statistical analysis was conducted using SPSS version 22.0.ResultsDisease progression was significantly correlated with ultrasound findings (P = .041 for the right eye and P = .037 for the left eye) and with Expanded Disability Status Scale (EDSS) score at the end of the follow-up period (P = .07 for the right eye and P = .043 for the left eye). No statistically significant differences were found with relation to relapses or other clinical variables.DiscussionUltrasound measurement of optic nerve diameter constitutes a useful, predictive factor for the evaluation of patients with MS. Smaller diameters are associated with poor clinical progression and greater disability (measured by EDSS). (AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Nervo Óptico / Ultrassonografia / Olho / Esclerose Múltipla Limite: Humanos Idioma: Espanhol Revista: Neurología (Barc., Ed. impr.) Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen Macarena/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Nervo Óptico / Ultrassonografia / Olho / Esclerose Múltipla Limite: Humanos Idioma: Espanhol Revista: Neurología (Barc., Ed. impr.) Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Virgen Macarena/España
...