The diagnostic value of miR-21 combined with CT in patients with liver cancer
Feng, Y. S; Zhou, J. M; Sun, C. H; Zhu, J; Yang, J; Guo, L.
Afiliação
  • Feng, Y. S; The First Affiliated Hospital of Nanyang Medical College. Department of CT Room. Henan. China
  • Zhou, J. M; Yantaishan Hospital. Department of Ultrasound Diagnosis. Yantai. China
  • Sun, C. H; The Third People’s Hospital of Qingdao. Department of Hepatobiliary Surgery. Qingdao. China
  • Zhu, J; The People’s Hospital of Zhangqiu Area. Department of Respiratory Medicine. Jinan. China
  • Yang, J; The People’s Hospital of Zhangqiu Area. Department of Clinical Laboratory. Jinan. China
  • Guo, L; Shandong University. Cheeloo College of Medicine. Jinan Central Hospital. Shandong. China
Clin. transl. oncol. (Print) ; 23(6): 1238-1244, jun. 2021. graf
Artigo em Inglês | IBECS | ID: ibc-221344
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
ABSTRACT
Purpose To explore the diagnostic value of miR-21 combined with computed tomography (CT) in patients with liver cancer. Methods A total of 112 patients in our hospital were confirmed liver cancer by examination, and were collected as cancer group. Another 100 patients with hepatic focal nodular hyperplasia in the same period were collected as control group. The diagnostic value of miR-21 and CT on liver cancer was observed. Results The level of miR-21 in cancer group was significantly higher than that in control group, the difference was statistically significant (p < 0.05). The alpha-fetoprotein (AFP) level was tested. It was found that the AFP level in cancer group was significantly higher than that in control group (p < 0.001). The correlation between AFP and miR-21 levels in liver cancer patients was detected. It turned out that AFP and miR-21 had correlation. According to receiver operating curve (ROC) calculation results, the best cut-off value for miR-21 diagnosis was 4.142. The sensitivity, specificity and accuracy of diagnosis of miR-21 alone were 64.29%, 87.00% and 75.00%, respectively. The sensitivity, specificity and accuracy of diagnosis of CT alone were 91.07%, 62.00% and 77.36%, respectively. There were 108 cases of true positive and 80 cases of true negative after combined diagnosis in the two groups. The sensitivity, specificity and accuracy of combined diagnosis were 96.43%, 80.00% and 88.68%, respectively. Comparing the value of single diagnosis and combined diagnosis, we found that the accuracy, sensitivity and specificity of combined diagnosis were significantly higher than that of single diagnosis (p < 0.05). Conclusion CT combined with miR-21 has great diagnostic value in liver cancer and may be a potential diagnostic indicator for liver cancer (AU)
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Tomografia Computadorizada por Raios X / MicroRNAs / Neoplasias Hepáticas Limite: Humanos Idioma: Inglês Revista: Clin. transl. oncol. (Print) Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: Shandong University/China / The First Affiliated Hospital of Nanyang Medical College/China / The People’s Hospital of Zhangqiu Area/China / The Third People’s Hospital of Qingdao/China / Yantaishan Hospital/China
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Tomografia Computadorizada por Raios X / MicroRNAs / Neoplasias Hepáticas Limite: Humanos Idioma: Inglês Revista: Clin. transl. oncol. (Print) Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: Shandong University/China / The First Affiliated Hospital of Nanyang Medical College/China / The People’s Hospital of Zhangqiu Area/China / The Third People’s Hospital of Qingdao/China / Yantaishan Hospital/China
...