RESUMEN
Introducción y

objetivo:

Para obtener buenos resultados en reconstrucción mamaria autóloga con colgajo de dorsal ancho se requiere verificar la presencia de una vascularización tóracodorsal adecuada. En el presente trabajo evaluamos la aportación de la ecografía Doppler-Dúplex para la localización de la arteria torácodorsal, previa a la reconstrucción mamaria diferida con colgajo de dorsal ancho. Material y

método:

Revisión de 51 pacientes con antecedentes de cirugía axilar por cáncer de mama candidatas a reconstrucción diferida con colgajo homolateral del músculo dorsal ancho. La exploración ecográfica la realizó un solo radiólogo utilizando la modalidad ecográfica Doppler-Dúplex.

Resultados:

Entre las 51 pacientes, se localizó la arteria tóracodorsal mediante ecografía en 39 casos (76.47%). En 12 casos no se pudo localizar o bien su identificación resultó dudosa. Entre estos 12 casos, en 8 se realizó angio-tomografía computarizada o bien angio-resonancia magnética que identificaron la arteria en 5 casos. En los otros 3, las pacientes rechazaron las exploraciones y no se sometieron a reconstrucción mediante la técnica estudiada o bien no se reconstruyeron. Se dispone de datos confirmados en 47 casos, entre los cuales no se ha visualizado vascularización tóracodorsal en 3 casos, lo que supone un 6.38%. Los parámetros diagnósticos resultantes fueron sensibilidad 88.63%; especificidad 100%; valor predictivo positivo 100%;y valor predictivo negativo 37.50%, con una exactitud del 89.36%.

Conclusiones:

En base a nuestra experiencia podemos concluir que, siempre que se disponga de la experiencia y los medios técnicos adecuados, la ecografía Doppler-Dúplex debería ser el primer procedimiento a utilizar para la evaluación de la vascularización tóracodorsal. y en el caso de no reunir tales requisitos o bien si la ecografía fuera dudosa/negativa, realizar otros métodos como la angio-tomografía computarizada o la angio-resonancia magnética(AU).
ABSTRACT
Background and

objective:

To obtain good results with autologous latissimus dorsi flap in breast reconstruction it's necessary to verify the presence of adequate thoracodorsal vascularity. In this paper we evaluate the contribution of Doppler-Duplex ultrasound for the localization of the thoracodorsal vessels prior to delayed breast reconstruction with a dorsal fap.

Methods:

Review of 51 patients with a history of axillary surgery for breast cancer, candidates for delayed breast reconstruction with an ipsilateral flap of the latissimus dorsi muscle. The ultrasound examination was performed by a single radiologist using the Doppler-Duplex ultrasound modality.

Results:

Among the 51 patients, the thoracodorsal artery was located by ultrasound in 39 cases (76.47%). In 12 cases it could not be located or its identification was doubtful. Among these 12 cases, 8 underwent computed tomography angiography or magnetic resonance angiography, which identified the artery in 5 cases. In the remaining 3 cases the patients refused such examinations and did not undergo reconstruction. Confirmed data are available in 47 cases, among which thoracodorsal vasculature was not visualized in 3 cases, which represents 6.38%,The resulting diagnostic parameters were sensitivity 88.63%; specificity 100%; positive predictive value 100%; and negative predictive value 37.50%, with an accuracy of 89.36%.

Conclusions:

From our experience we can conclude that,when the appropriate experience and equipment are available, Doppler-Duplex ultrasound should be the first procedure to be used for the evaluation of the thoracodorsal vasculature. And in the case of not meeting these requirements or the ultrasound was doubtful/negative, perform other methods such as computed tomography angiography or magnetic resonance angiography. Level of evidence 5c Diagnostic.(AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Mama / Neoplasias da Mama / Valor Preditivo dos Testes / Mamoplastia / Ultrassonografia Doppler Dupla Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Cir. plást. ibero-latinoam Ano de publicação: 2023 Tipo de documento: Artigo Instituição/País de afiliação: Grupo Radiológico PRETEIMAGEN/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Mama / Neoplasias da Mama / Valor Preditivo dos Testes / Mamoplastia / Ultrassonografia Doppler Dupla Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Cir. plást. ibero-latinoam Ano de publicação: 2023 Tipo de documento: Artigo Instituição/País de afiliação: Grupo Radiológico PRETEIMAGEN/España
...