Binocular vision parameters and visual performance in bilateral keratoconus corrected with spectacles versus rigid gas-permeable contact lenses / Parámetros de visión binocular y rendimiento visual en queratocono bilateral corregido con gafas versus lentes de contacto rígidos permeables al gas
J. optom. (Internet)
; 17(3): [100514], jul.-sept2024. tab
Artigo
em Inglês
| IBECS
| ID: ibc-231876
Biblioteca responsável:
ES1.1
Localização: ES15.1 - BNCS
ABSTRACT
Purpose:
To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia.Methods:
A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached.Results:
Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges.Conclusions:
Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.(AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Testes Visuais
/
Visão Binocular
/
Lentes de Contato
/
Óculos
/
Ceratocone
Limite:
Adolescente
/
Feminino
/
Humanos
/
Masculino
País/Região como assunto:
América do Sul
/
Colômbia
/
México
Idioma:
Inglês
Revista:
J. optom. (Internet)
Ano de publicação:
2024
Tipo de documento:
Artigo
Instituição/País de afiliação:
Autonomous University of Aguascalientes/Mexico
/
University Foundation Area Andina/Colombia