[Translated article] Validation of the Spanish version of the modified Harris score / Validación de la versión española de la escala de Harris modificada
Rev. esp. cir. ortop. traumatol. (Ed. impr.)
; 68(2): T121-T127, Mar-Abr. 2024. ilus, tab
Article
em En
| IBECS
| ID: ibc-231890
Biblioteca responsável:
ES1.1
Localização: ES15.1 - BNCS
RESUMEN
Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)
ABSTRACT
Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)
Palavras-chave
Texto completo:
1
Coleções:
06-national
/
ES
Base de dados:
IBECS
Assunto principal:
Artroplastia de Quadril
/
Procedimentos Cirúrgicos Robóticos
/
Quadril
/
Fraturas do Quadril
Limite:
Female
/
Humans
/
Male
País/Região como assunto:
Europa
Idioma:
En
Revista:
Rev. esp. cir. ortop. traumatol. (Ed. impr.)
Ano de publicação:
2024
Tipo de documento:
Article