Laringoscopio óptico Airtraq® / Airtraq® optical laryngoscopy
An. sist. sanit. Navar
; 32(1): 75-83, ene.-abr. 2009. ilus, tab
Artigo
em Espanhol
| IBECS
| ID: ibc-61434
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
La intubación endotraqueal mediante laringoscopiadirecta sigue siendo el gold standard entre todas lastécnicas de aislamiento de la vía aérea. Se trata, generalmente,de una maniobra segura, pero en ocasionespuede convertirse en una situación de extrema emergenciaante una vía aérea difícil imprevista.El laringoscopio Airtraq® (Prodol Meditec, Vizcaya,Spain) representa una nueva herramienta a utilizaren el paciente. Su fácil aprendizaje y sencillo manejo loconvierten en un práctico dispositivo en muchas indicacionesde manejo de la vía aérea. Ha mostrado ventajasfrente al laringoscopio de Macintosh en pacientes convía aérea de difícil manejo y en situaciones adversasfuera del medio quirúrgico, lográndose la intubaciónendotraqueal de forma sencilla tras intentos ineficacescon laringoscopios convencionales.Los mayores beneficios con el uso del laringoscopioAirtraq® se han visto en pacientes con una marcadalimitación de la movilidad cervical y aquellos, comoembarazadas y obesos, en los que por razones anatómicasla vía aérea se ve distorsionada(AU)
ABSTRACT
Endotracheal intubation using direct laryngoscopycontinues to be the gold standard amongst all thetechniques for isolating the airway. Generally this is asecure manoeuvre, but it might become a situation ofextreme emergency when dealing with an unexpecteddifficult airway.The Airtraq® laryngoscope (Prodol Meditec, Vizcaya,Spain) is a new tool for use with the patient. Thefact that it is easy to learn to use and simple to handlemakes it a practical device in many situations wheremanaging the airway is indicated. Its advantages overthe Macintosh laryngoscope have been demonstratedin patients with an airway that it is difficult to manageand in adverse situations outside the surgical setting,when endotracheal intubation has been achieved in asimple way following unsuccessful attempts with conventionallaryngoscopes.The greatest benefits in using the Airtraq® laryngoscopehave been shown in patients with a pronouncedlimitation of cervical mobility, and in those wherethe airway is distorted for anatomical reasons, such aspregnant women and obese patients(AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Laringoscópios
/
Intubação Intratraqueal
/
Laringoscopia
Tipo de estudo:
Estudo de etiologia
/
Fatores de risco
Limite:
Humanos
Idioma:
Espanhol
Revista:
An. sist. sanit. Navar
Ano de publicação:
2009
Tipo de documento:
Artigo
Instituição/País de afiliação:
Clínica Universitaria de Navarra/España
/
Hospital de Navarra/España