Your browser doesn't support javascript.
loading
Diseño y desarrollo de un sistema de osteosíntesis para la reconstrucción-artrodesis mínimamente invasiva de fracturas intraarticulares de calcáneo / Design and development of an osteosynthesis system for minimally invasive reconstruction-arthrodesis of calcaneal intra-articular fractures
López-Oliva Muñoz, F; Sánchez-Lorente, T; López-Hernández, G; Rodríguez-Macías, M. J; Forriol, F.
Afiliação
  • López-Oliva Muñoz, F; Centro de Prevención y Rehabilitación FREMAP. Madrid. España
  • Sánchez-Lorente, T; Centro de Prevención y Rehabilitación FREMAP. Madrid. España
  • López-Hernández, G; Centro de Prevención y Rehabilitación FREMAP. Madrid. España
  • Rodríguez-Macías, M. J; Centro de Prevención y Rehabilitación FREMAP. Madrid. España
  • Forriol, F; Centro de Prevención y Rehabilitación FREMAP. Madrid. España
Rev. ortop. traumatol. (Madr., Ed. impr.) ; 51(2): 94-101, mar.-abr. 2007. ilus
Artigo em Es | IBECS | ID: ibc-65534
Biblioteca responsável: ES15.1
Localização: ES15.1 - BNCS
ABSTRACT
Objetivo. Desarrollar una instrumentación que restaure la forma del calcáneo fracturado y facilite la artrodesis primaria de la articulación subastragalina mínimamente invasiva en las fracturas intraarticulares graves del calcáneo. Material y método. Se estudió un nuevo sistema de osteosíntesis para las fracturas de calcáneo en tres fases consecutivas a) diseño del sistema, b) ensayos biomecánicos y c) prueba de los prototipos en el cadáver. Resultados. Los fundamentos del diseño original han sido validados con mínimos cambios. Desde el punto de vista biomecánico el implante desarrollado ha superado las pruebas de resistencia y fatiga y ha demostrado un buen manejo quirúrgico en el cadáver. Conclusiones. El implante diseñado cumple sus objetivos, se adapta a las condiciones mecánicas y dimensionales del calcáneo
ABSTRACT
Purpose. To develop instruments that can restore the shape of a fractured calcaneus and facilitate minimally invasive primary arthrodesis of the subtalar joint in severe calcaneal intraarticular fractures. Materials and methods. We studied a new osteosynthesis system for calcaneal fractures in three consecutive phases a) system design, b) biomechanical tests and c) prototype testing in cadavers. Results. The basic characteristics of the original design were validated with minimal changes. From the biomechanical point of view the implant developed has passed strength and fatigue tests and has shown itself to provide good surgical management in cadavers. Conclusions. The implant designed achieves its purpose, and adapts to the mechanical conditions and dimensions of the calcaneal bone (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Artrodese / Calcâneo / Fixação Interna de Fraturas Limite: Humanos Idioma: Espanhol Revista: Rev. ortop. traumatol. (Madr., Ed. impr.) Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Centro de Prevención y Rehabilitación FREMAP/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Artrodese / Calcâneo / Fixação Interna de Fraturas Limite: Humanos Idioma: Espanhol Revista: Rev. ortop. traumatol. (Madr., Ed. impr.) Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Centro de Prevención y Rehabilitación FREMAP/España
...