Your browser doesn't support javascript.
loading
Eco-doppler transcraneal. Utilización en anestesiología / Transcranial doppler ultrasonography. Use in anesthesilogy
Calvo Vecino, J. M; Abad Gurumeta, A; Garrido Reche, E; Gil Lapetra, C; García Álvarez, R; Gilsanz Rodríguez, F.
Afiliação
  • Calvo Vecino, J. M; Hospital Infanta Leonor. Madrid. España
  • Abad Gurumeta, A; Hospital Infanta Cristina. Madrid. España
  • Garrido Reche, E; Hospital Infanta Leonor. Madrid. España
  • Gil Lapetra, C; Hospital Infanta Leonor. Madrid. España
  • García Álvarez, R; Hospital Infanta Leonor. Madrid. España
  • Gilsanz Rodríguez, F; Hospital Universitario La Paz. Madrid. España
Actual. anestesiol. reanim ; 18(3): 85-91, jul.-sept. 2008. ilus
Artigo em Es | IBECS | ID: ibc-69722
Biblioteca responsável: ES15.1
Localização: ES15.1 - BNCS
RESUMEN
El efecto Doppler ha sido utilizado en numerosas parcelas científicas, incluida la anestesiología. La información que muestra la ecografía Doppler transcraneal relativa a los índices de pulsatilidad y resistencia, derivadas del estudio de la velocidad de flujo sanguíneo intracerebral, supone un avance en el estudio del comportamiento de los distintos fármacos y técnicas anestésicas. Se muestra aquí una breve descripción de los fundamentos de uso en anestesiología y la utilidad que puede presentar como sistema de monitorización compleja aunque no invasiva, en el conocimiento de los patrones específicos de comportamiento que presentan los fármacos más utilizados actualmente respecto de la velocidad de flujo intracranial (AU)
ABSTRACT
The Doppler effect is used in many scientific fields, even anaesthesiology. The inform data showed by the transcranial Doppler ultrasound, regarding to pulsatility or resistance index, derived from the study of the behaviour of the different drugs and anaesthetic techniques. We present here a brief description of the use basis in anaesthesiology and the utility that can present like a complex although non-invasive monitoring system in knowledge of the specific pattern behaviour that the more actually utilized drugs present respect to the cerebral blood flow velocity(AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Efeito Doppler / Anestesia Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Actual. anestesiol. reanim Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Infanta Cristina/España / Hospital Infanta Leonor/España / Hospital Universitario La Paz/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Efeito Doppler / Anestesia Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Actual. anestesiol. reanim Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Infanta Cristina/España / Hospital Infanta Leonor/España / Hospital Universitario La Paz/España
...