Your browser doesn't support javascript.
loading
Utilidad de la reconstrucción de proyección de máxima intensidad para la lectura de los estudios realizados en un programa de detección precoz de cáncer de pulmón por tomografía computarizada multicorte de baja dosis de radiación / Usefulness of maximum intensity projections in low-radiation multislice CT lung cancer screening
Bastarrika Alemañ, G; Domínguez Echávarri, PD; Noguera Tajadura, JJ; Arraiza Sarasa, M; Zudaire Díaz-Tejeiro, B; Zulueta Francés, JJ.
Afiliação
  • Bastarrika Alemañ, G; Clínica Universitaria de Navarra. Pamplona. España
  • Domínguez Echávarri, PD; Clínica Universitaria de Navarra. Pamplona. España
  • Noguera Tajadura, JJ; Clínica Universitaria de Navarra. Pamplona. España
  • Arraiza Sarasa, M; Clínica Universitaria de Navarra. Pamplona. España
  • Zudaire Díaz-Tejeiro, B; Clínica Universitaria de Navarra. Pamplona. España
  • Zulueta Francés, JJ; Clínica Universitaria de Navarra. Pamplona. España
Radiología (Madr., Ed. impr.) ; 50(3): 231-237, mayo 2008. ilus
Artigo em Espanhol | IBECS | ID: ibc-79010
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Objetivo. Valorar la exactitud diagnóstica de reconstrucciones axiales no solapadas de proyección de máxima intensidad (MIP) de 10 mm de grosor, para detectar nódulos pulmonares en sujetos que participan en un programa de detección precoz de cáncer de pulmón (DPCP) por tomografía computarizada multicorte (TCMC) de baja dosis de radiación. Material y métodos. Se evaluaron 52 estudios consecutivos de TCMC de baja dosis de radiación de fumadores asintomáticos incluidos en un programa de DPCP (imágenes axiales de 1,25 mm). Se realizaron reconstrucciones MIP axiales de 10 mm de grosor de corte (30 imágenes) de forma retrospectiva que fueron interpretadas de forma independiente, sin conocer el informe radiológico inicial. Se consideraron todos los nódulos detectados independientemente de su tamaño o consistencia. Para cada nódulo el estándar de referencia fue determinado mediante doble lectura y consenso. Resultados. Se identificaron 162 nódulos pulmonares (tamaño medio 3,9 mm, DE 1,7). La reconstrucción MIP detectó 150 nódulos (S = 92,6%). En la valoración radiológica inicial se detectaron 108 nódulos (S = 66,7%). La reconstrucción MIP detectó 54 (33,3%) nódulos no informados inicialmente (tamaño medio 3,4 mm; DE 1,2) y no detectó 12 (7,4%) de los nódulos descritos (tamaño medio 2,91 mm; DE = 0,8). El MIP detectó los 35 nódulos * 5 mm, (S =100) de los cuáles solo se informaron 27 (S = 77%) en el informe radiológico inicial. La reconstrucción MIP permitió detectar con exactitud todos los nódulos * 5 mm y más nódulos pulmonares que las imágenes axiales convencionales de 1,25 mm (p < 0,01). Conclusión. La introducción de un protocolo de lectura de reconstrucciones MIP axiales no solapadas de 10 mm en un programa de DPCP por TCMC de baja dosis de radiación permite detectar nódulos con mayor exactitud y en menor tiempo que utilizando las imágenes axiales convencionales de 1,25 mm (AU)
ABSTRACT
Objective. To evaluate the diagnostic accuracy of non-overlapping 10-mm-thick axial maximum intensity projections (MIP) in the detection of pulmonary nodules in subjects participating in a lung cancer screening program (LCSP) using multislice computed tomography (MSCT) with a low dose of radiation. Material and methods. We evaluated 52 consecutive low-radiation MSCT studies in asymptomatic smokers included in an LCSP (1.25 mm axial images). Axial MIPs with 10mm slice thickness (30 images) were performed and evaluated retrospectively; readers were blind to the initial radiological report. All nodules detected were considered, regardless of their size or consistency. The standard of reference was determined by double reading and consensus for each nodule. Results. A total of 162 pulmonary nodules (mean size 3.9 mm, sd 1.7) were detected. MIP reconstruction detected 150 nodules (S = 92.6%). The initial radiological evaluation detected 108 nodules (S = 66.7%). MIP reconstruction detected 54 (33.3%) nodules that were not reported initially (mean size 3.4 mm; sd 1.2) but failed to detect 12 (7.4%) of the nodules reported initially (mean size 2.91 mm; sd 0.8). MIP detected all 35 nodules * 5 mm, (S =100), whereas the initial radiological evaluation only detected 27 (S = 77%). MIP reconstruction enabled more of the nodules to be detected than the 1.25-mm conventional axial slices (p < 0.01). Conclusion. The introduction of non-overlapping 10-mm-thick axial MIP reconstructions in a low-radiation LCSP using MSCT enabled nodules more accurate and faster detection of pulmonary nodules in comparison with 1.25 mm conventional axial slices (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Diagnóstico Precoce / Neoplasias Pulmonares Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo observacional / Estudo prognóstico / Estudo de rastreamento Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Clínica Universitaria de Navarra/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Diagnóstico Precoce / Neoplasias Pulmonares Tipo de estudo: Estudo diagnóstico / Guia de prática clínica / Estudo observacional / Estudo prognóstico / Estudo de rastreamento Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Clínica Universitaria de Navarra/España
...