Catéter-fístula: una nueva alternativa en la punción de accesos vasculares / Fistula catheter: a new alternative in venous access puncture
Martínez Ocaña, Olga; Rodríguez Estaire, Jaime; Ruiz Sanz, Beatriz; Martín Navarro, Juan Antonio; Mérida Herrero, Eva.
Afiliação
  • Martínez Ocaña, Olga; Centro de Hemodiálisis San Luciano. Fresenius Medical Care. Madrid. España
  • Rodríguez Estaire, Jaime; Centro de Hemodiálisis San Luciano. Fresenius Medical Care. Madrid. España
  • Ruiz Sanz, Beatriz; Centro de Hemodiálisis San Luciano. Fresenius Medical Care. Madrid. España
  • Martín Navarro, Juan Antonio; Centro de Hemodiálisis San Luciano. Fresenius Medical Care. Madrid. España
  • Mérida Herrero, Eva; Centro de Hemodiálisis San Luciano. Fresenius Medical Care. Madrid. España
Rev. Soc. Esp. Enferm. Nefrol ; 13(2): 105-111, abr.-jun. 2010. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-79448
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Es imprescindible un acceso vascular adecuado para obtener una hemodiálisis óptima. El daño causado por la punción de la aguja convencional o complicaciones intradiálisis derivadas del movimiento del brazo pueden comprometer la supervivencia del acceso. Otro factor esencial en la calidad de la hemodiálisis, íntimamente relacionado con el calibre de la aguja, es conseguir un mayor flujo sanguíneo eficaz. El catéter-fístula, una nueva cánula de punción de fluoruroplástico, disminuye el daño en la pared interna del acceso y presenta un menor calibre de punción con un mayor calibre interior, lo que le permite alcanzar mayores flujos con una máxima eficacia depuradora y menores complicaciones vasculares. El objetivo de este estudio prospectivo fue comparar el uso del catéter-fístula con el uso de la aguja convencional. Se realizaron 18 sesiones de hemodiálisis con cada uno de los dispositivos en pacientes estables y con buen acceso vascular, recogiéndose en todos los casos el flujo obtenido, las presiones y otros parámetros del monitor, analíticas e incidencias. Los resultados han demostrado que la utilización del catéter-fístula disminuyó la presión arterial y la presión venosa, sin disminuir la eficacia dialítica, en consecuencia, mejoró el perfil hemodinámico. Mejoró significativamente el flujo de sangre real, el número de litros dializados y el Kt. El menor trauma mecánico producido en el acceso vascular permitió disminuir la dosis de heparina, el tiempo de hemostasia y hubo una reducción de las complicaciones vasculares extravasación y resangrado. Siendo bien tolerada la punción, hay un leve empeoramiento en la sensación dolorosa, justificada por la inexperiencia del manejo. La mejoría en los parámetros dinámicos abren las posibilidades de conseguir mayor eficacia dialítica al hacer factible la utilización de mayores flujos sanguíneos con presiones más adecuadas (AU)
ABSTRACT
Adequate vascular access is essential in order toobtain optimal haemodialysis. The damage caused by conventional needle puncture or intradialytic complications deriving from the movement of the arm can compromise the survival of the access. Another essential factor in the quality of the haemodialysis, closely related to the calibre of the needle, is obtaining a greater efficient blood flow. The fistula catheter, a new puncture cannula made of fluoroplastic, reduces the damage to the internal wall of the access and presents a lower puncture calibre with a higher interior calibre, which allows it to reach better flows with maximum efficiency and fewer vascular complications. The aim of this prospective study was to compare the use of the fistula catheter with the use of the needle. Eighteen haemodialysis sessions were carried out with each of the devices in stable patients with good vascular access, recording in all cases the flow obtained, pressures and other monitor parameters, test results and incidents. The results have shown that the use of the fistula catheter reduced the arterial pressure and venous pressure, without reducing the dialytic efficiency, and consequently the haemodynamic profile improved. The actual blood flow, number of litres dialysed and Kt improved significantly. The lesser mechanical trauma caused in the vascular access made it possible to reduce the dose of heparin, the haemostasis time and there was a reduction in vascular complications extravasation and rebleeding. While the puncture is well tolerated, there is a slight worsening in the feeling of pain, explained by the lack of experience in handling. The improvement in dynamic parameters opens up the possibilities of achieving greater dialytic efficiency by making it feasible to use greater blood flows with more adequate pressures (AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Pressão Venosa / Biópsia / Cateterismo / Cateterismo Cardíaco / Fístula Tipo de estudo: Estudo diagnóstico / Estudo observacional / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. Soc. Esp. Enferm. Nefrol Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Centro de Hemodiálisis San Luciano. Fresenius Medical Care/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Pressão Venosa / Biópsia / Cateterismo / Cateterismo Cardíaco / Fístula Tipo de estudo: Estudo diagnóstico / Estudo observacional / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. Soc. Esp. Enferm. Nefrol Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Centro de Hemodiálisis San Luciano. Fresenius Medical Care/España
...