Incorporación de la ecografía y la punción de tiroides a la actividad de endocrinología en una consulta de alta resolución / Routine performance of thyroid ultrasound and fine-needle aspiration biopsy in the setting of a high-resolution endocrinology practice
Endocrinol. nutr. (Ed. impr.)
; 57(2): 43-48, feb. 2010. tab
Artigo
em Espanhol
| IBECS
| ID: ibc-80308
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción La PAAF es el procedimiento de referencia para el diagnóstico del nódulo tiroideo. Material y métodos La incorporación de la ecografía cervical y la PAAF guiada por ecografía a la actividad del médico endocrinólogo permite abordar esta patología en el ámbito de una consulta de alta resolución, con la consiguiente reducción en el coste del proceso y en la demora del diagnóstico. Resultados Presentamos los resultados iniciales de esta consulta; tras los dos primeros años y con un total de 286 punciones, nos situamos en un 72,72% de citologías aptas para diagnóstico, siguiendo una curva de aprendizaje acorde con el tiempo transcurrido y con la experiencia previa. Observamos una mayor dificultad en la obtención de citologías óptimas para diagnóstico en los nódulos de menor tamaño. En resumen, hemos incorporado la ecografía y la PAAF guiada por ecografía de manera satisfactoria a la consulta endocrinológica. Conclusión El uso de manera rutinaria de la ecografía en la consulta de endocrinología permite agilizar el manejo de la patología nodular tiroidea (AU)
ABSTRACT
Introduction Fine-needle aspiration biopsy (FNAB) is considered the reference diagnostic procedure for thyroid nodules. Materials and methods Routine performance of thyroid ultrasound and ultrasound-guided FNAB by endocrinologists allows a more efficient approach in the setting of a high-resolution practice, thus reducing costs and the time elapsed until diagnosis. Results We present our initial results of this procedure 2 years after its introduction, with a total of 286 biopsies performed. After a progressive learning curve over time and according to the endocrinologists previous experience, 72.72% samples were considered satisfactory for diagnosis. Greater difficulty was observed in obtaining optimal cytological specimens in smaller nodules. In conclusion, we have successfully incorporated thyroid ultrasound and ultrasound-guided FNAB into routine endocrine practice. Conclusion Routine performance of thyroid ultrasound in endocrine practice will considerably aid the management of nodular thyroid disease (AU)
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Doenças da Glândula Tireoide
/
Neoplasias da Glândula Tireoide
/
Ultrassonografia de Intervenção
/
Biópsia por Agulha Fina
Tipo de estudo:
Estudo de etiologia
Limite:
Adulto
/
Feminino
/
Humanos
/
Lactente
/
Masculino
País/Região como assunto:
Europa
Idioma:
Espanhol
Revista:
Endocrinol. nutr. (Ed. impr.)
Ano de publicação:
2010
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital Universitario Son Dureta/España