Vitrectomía vía pars plana e implante simultáneo de dispositivo de drenaje para glaucoma / Simultaneous pars plana vitrectomy and glaucoma drainage device implant
Suárez-Fernández, M. J; Gutiérrez-Díaz, E; Julve San Martín, A; Fernández-Reyes, M. F; Mencía-Gutiérrez, E.
Afiliação
  • Suárez-Fernández, M. J; Hospital Universitario 12 de Octubre. Servicio de Oftalmología. Madrid. España
  • Gutiérrez-Díaz, E; Hospital Universitario 12 de Octubre. Servicio de Oftalmología. Madrid. España
  • Julve San Martín, A; Hospital Universitario 12 de Octubre. Servicio de Oftalmología. Madrid. España
  • Fernández-Reyes, M. F; Hospital Universitario 12 de Octubre. Servicio de Oftalmología. Madrid. España
  • Mencía-Gutiérrez, E; Hospital Universitario 12 de Octubre. Servicio de Oftalmología. Madrid. España
Arch. Soc. Esp. Oftalmol ; 85(3): 97-102, mar. 2010. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-85861
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Evaluar los resultados en cuanto a control de presión intraocular (PIO) y agudezavisual (AV) tras cirugía de implante de drenaje para glaucoma (DDG) combinada con vitrectomíapars plana (VPP) simultánea.Material y

métodos:

Revisión retrospectiva de 8 ojos (7 pacientes). El diagnóstico era glaucomaneovascular (GNV) secundario a retinopatía diabética proliferativa en 4 ojos, en los quese colocó un implante de Molteno de doble plato, y glaucoma secundario (GS) a cirugía decatarata complicada en 3 ojos y a traumatismo penetrante en otro, en los que se usó unaválvula de Ahmed.

Resultados:

La PIO media pasó de 35,77 mmHg (20-50) preoperatoria a 11,5 mmHg (2-20)postoperatoria, y el número de fármacos hipotensores medio de 2,33 (0-3) preoperatorio a0,62 (0-3) postoperatorio. En los GNV, la AV preoperatoria era percepción de luz o contardedos, y se perdió en 3 ojos. En los GS era inferior a 0,1, aumentando hasta una AV mediade 0,42 (0,1-0,8) a los 3 meses. El seguimiento medio fue de 10,12 meses (5-27). Las complicacionesfueron obstrucción del tubo por fibrina en 2 casos, uno de los cuales (GNV) presentóuna hemorragia supracoroidea tras la desobstrucción y evolución a ptisis bulbi, extrusióndel reservorio en un caso, y descompensación corneal tardía en un caso.

Conclusiones:

En los GS los resultados han sido buenos, con mejoría de la AV y PIO controlada.En los GNV se consiguió controlar la PIO y evitar dolor, pero los resultados visualesfueron malos por la enfermedad de base(AU)
ABSTRACT

Purpose:

To evaluate intraocular pressure (IOP) and visual acuity (VA) results after glaucomadrainage device (GDD) implantation combined with simultaneous pars plana vitrectomy(PPV).Material and

methods:

Retrospective review of 8 eyes (7 patients). The diagnosis wasneovascular glaucoma (NVG) secondary to proliferative diabetic retinopathy in 4 eyes, in awhich a double plate Molteno implant was placed, and glaucoma secondary (GS) tocomplicated cataract surgery in 3 eyes and penetrating trauma in one eye, in which aglaucoma Ahmed valve was implanted.

Results:

Mean preoperative IOP was 35.77 mmHg (20-50) and 11.5 mmHg (2-20) postoperatively,and mean number hypotensive drugs was decreased from 2.33 (0-3) before surgery to 0.62(0-3) after it. Preoperative VA in NVG was light perception or counting fingers, and it waslost in three eyes. In GS, VA before surgery was below 0.1 in all eyes, and three months aftersurgery mean VA was 0.42 (0.1-0.8). Mean follow-up was 10.12 months (5-27). Thecomplications were tube obstruction in two cases, one of these presenting also asuprachoroidal hemorrage and ptisis bulbi, plate exposure in one case, and bullouskeratopathy as a late complication in another eye.

Conclusions:

The VA and IOP were well controlled with this procedure in GS. In NVG, IOP wascontrolled, but visual results were poor due to complications and the underlyingpathology(AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Vitrectomia / Glaucoma Neovascular / Implantes para Drenagem de Glaucoma Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario 12 de Octubre/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Vitrectomia / Glaucoma Neovascular / Implantes para Drenagem de Glaucoma Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario 12 de Octubre/España
...