Evolución del diámetro iliaco tras resección de aneurisma aórtico e interposición de injerto aorto-aórtico / Follow-up of iliac diameter in patients after open abdominal aortic aneurysm repair with an aorto-aortic prosthetic graft
Angiología
; 62(6): 219-224, nov.-dic. 2010. tab, graf
Artigo
em Espanhol
| IBECS
| ID: ibc-88777
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción:
Los aneurismas de arteria iliaca después de la reparación de un aneurisma aórtico abdominal (AAA) son poco comunes y no se ha protocolizado el seguimiento del diámetro iliaco.Objetivo:
Evaluar la evolución del tamaño de las arterias iliacas mediante eco-doppler en pacientes intervenidos de AAA e interposición de injerto recto. Material ymétodos:
Estudio transversal de pacientes intervenidos de AAA entre enero de 1999 y marzo de 2008 a los que se les realiza un eco-doppler para valorar el diámetro de las arterias iliacas. Se recogen 45 pacientes. Variables estudiadas diámetro iliaco preoperatorio (angio-tomografía computarizada) y postoperatorio, así como factores de riesgo vascular y comorbilidades. Se realizan las pruebas de la t de Student, Chi 2 y tablas de supervivencia.Resultados:
Media de edad 69 años (desviación estándar [DE] 6,8). Seguimiento medio 4,5 años (DE 1,89). Tamaño preoperatorio medio de arterias iliacas 13 mm (DE 0,45), en el seguimiento 17 mm (DE 0,52), p = 0,001. Un 19 % de las iliacas presentó crecimiento durante el seguimiento. Se observó un menor crecimiento en pacientes con diabetes mellitus (0/24 %, riesgo relativo [RR] 0,76; intervalo de confianza [IC] 95 % 0,7-0,9). No se ha podido determinar una correlación tiempo/crecimiento. Ningún paciente precisó tratamiento durante el seguimiento.Conclusión:
Aunque en nuestra serie se demuestra un crecimiento significativo durante el seguimiento, no está justificado un protocolo de seguimiento ecográfico de arterias iliacas en este contexto por la baja/nula necesidad de tratamiento quirúrgico posterior(AU)ABSTRACT
Introduction:
Iliac artery aneurysms are uncommon and there is current no protocol for the follow-up.Aim:
To evaluate the progress of the diameter of the iliac arteries by echo-doppler in patients undergoing abdominal aortic aneurysm (AAA) open repair with an aorto-aortic prosthetic graft. Material andmethods:
A cross-sectional study of patients undergoing AAA between January 1999 and March 2008, on whom an echo-doppler was performed to assess the diameter of iliac arteries. A total of 45 patients were included. The variables studied were pre- and post-operative iliac diameter (angio-computerized tomography), vascular risk factors and comorbidities. Student t test, Chi-square test were performed and survival tables constructed.Results:
The mean age was 69 years (SD 6.8). Follow-up 4.5 years (1.89). Preoperative mean size of iliac arteries 13 mm (0.45), follow-up 17 mm (0.52), p = 0.001. Overall, the diameter increased in 19 % iliac arteries during growth monitoring. There was a lower expansion rate in diabetic patients (0 %/24 %, relative risk [RR] 0.76, 95 % confidence interval [CI] 0.7-0.9). We were unable to determine a time/expansion rate correlation. No patient required a repeat operation during the follow-up.Conclusion:
Although our series showed a significant growth, the iliac arteries ultrasound follow-up is not justified, in this context, due to the low/no need for a subsequent surgical procedure(AU)
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Aneurisma Aórtico
/
Transplante
Tipo de estudo:
Estudo diagnóstico
/
Estudo de etiologia
/
Guia de prática clínica
/
Estudo observacional
/
Estudo de prevalência
/
Fatores de risco
Limite:
Idoso
/
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Angiología
Ano de publicação:
2010
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital Universitario Son Dureta/España