RESUMEN
Las determinaciones de la carga viral de los virus de la inmunodeficiencia humana tipo 1 (VIH-1) y de la hepatitis C (VHC) son marcadores fundamentales para el seguimiento y control de los pacientes infectados por estos virus. Los laboratorios de microbiología deben disponer de herramientas que garanticen la fiabilidad de sus resultados, entre ellas se encuentran los programas de intercomparación externos. En el presente número se muestra el análisis de resultados del Programa de Control de Calidad SEIMC de carga viral de ambos virus y del genotipado del VHC, realizados durante el año 2009.En el control del VIH-1 se remitieron 5 estándares, de los que 1 (plasma humano seronegativo) no contenía el virus, y los otros 4 consistían en plasma de 3 pacientes virémicos distintos en un intervalo de concentraciones entre 25 log10 copias/ml; 2 de ellos eran idénticos, con el fin de analizar la repetibilidad. Una parte significativa de los laboratorios obtuvo resultados fuera de los límites aceptables (media ± 0,2 log10 copias/ml), dependiendo del estándar y del método empleado, en promedio el (..) (AU)
ABSTRACT
Human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) viral load determinations are among the most important markers in the follow-up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of the results obtained by microbiology laboratories. This article summarizes the results obtained from the SEIMCs External Quality Control Program for HIV-1and HCV viral loads in 2009.In the HIV-1 program, a total of five standards were sent. One standard consisted of seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of2-5 log10 copies/mL; two of these standards were identical, aiming to determine repeatability. A significant proportion of the laboratories (21.5% on average) obtained values outside the accepted range (mean ± 0.2 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was very good, with up to 95% of laboratories reporting results within the accepted (..) (AU)
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Contexto em Saúde:
Agenda de Saúde Sustentável para as Américas
/
ODS3 - Saúde e Bem-Estar
Problema de saúde:
Objetivo 9: Redução de doenças não transmissíveis
/
Meta 3.3: Acabar com as doenças tropicais negligenciadas e combater as doenças transmissíveis
Base de dados:
IBECS
Assunto principal:
Infecções por HIV
/
Hepatite C
/
Carga Viral
Limite:
Humanos
Idioma:
Espanhol
Revista:
Enferm. infecc. microbiol. clín. (Ed. impr.)
Ano de publicação:
2011
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital Clínico Universitario/España
/
Programa de Control de Calidad Externo SEIMC/España