Your browser doesn't support javascript.
loading
Foco pulmonar facticio con 18F-FDG: posible error en la interpretación de la PET-CT / Lung hot spot as pitfall in PET-CT interpretation: focal lung uptake of 18F-fluorodeoxyglucose
Redal Peña, MC; Pena Pardo, FJ; Muñoz Iglesias, J; Crespo-Jara, A; Rebollo, J; Brugarolas Masllorens, A.
Afiliação
  • Redal Peña, MC; USP Hospital San Jaime. Fundación Tedeca. Alicante. España
  • Pena Pardo, FJ; USP Hospital San Jaime. Fundación Tedeca. Alicante. España
  • Muñoz Iglesias, J; USP Hospital San Jaime. Fundación Tedeca. Alicante. España
  • Crespo-Jara, A; USP Hospital San Jaime. Fundación Tedeca. Alicante. España
  • Rebollo, J; USP Hospital San Jaime. Fundación Tedeca. Alicante. España
  • Brugarolas Masllorens, A; USP Hospital San Jaime. Fundación Tedeca. Alicante. España
Rev. esp. med. nucl. (Ed. impr.) ; 30(4): 248-250, jul.-ago. 2011.
Artigo em Espanhol | IBECS | ID: ibc-89626
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Aportamos dos casos de pacientes oncológicos en seguimiento rutinario con este tipo de artefacto, sin correlato morfológico en la TAC. Se procedió a la repetición del estudio en uno de ellos, lo que permitió comprobar una normalización de dicha hipercaptación, orientando a un posible artefacto. La PET-TAC con FDG se ha convertido en una herramienta imprescindible en el manejo del paciente oncológico. La distribución normal de la FDG y los posibles artefactos (pitfalls), incluidos aquéllos derivados de la corrección de atenuación basada en la TAC, han sido descritos en diversas revisiones. Sin embargo, sólo recientemente se ha publicado algún caso de falso positivo en forma de captación focal pulmonar de FDG(AU)
ABSTRACT
18F-FDG PET-CT has become an essential tool in oncology patient management. The normal distribution of the FDG and the possible artifacts (pitfalls), including those from CT-based attenuation correction, have already been described in several reviews. However, only a few cases of FDG focal lung uptake have been reported recently. We present two cases of oncology patients during a routine follow-up with this type of pitfall, without morphological correlation in the CT scan. We repeated the study in one of them, which made it possible to verify normalization of the hyperuptake, orienting us towards a possible pitfall(AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. med. nucl. (Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: USP Hospital San Jaime/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. med. nucl. (Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: USP Hospital San Jaime/España
...